Articles

web how to perform dc internal resistance measurement with arbin

How to perform DC Internal Resistance measurement with Arbin?

By Arbin Team | September 22, 2025

Mechanism explanations: Arbin’s MITS software uses pulse method to calculate IR. In order to achieve better accuracy, the software measure the IR 10 times and take the average. The pulse looks like the graph bellows: IIR is the amplitude value T2 is the Extra Control value1 I0 is the offset […]

enhancing battery testing safety with a door switch interlock system

Enhancing Battery Testing Safety with a Door Switch Interlock System

By Arbin Team | September 14, 2025

I. Purpose and Applicability Battery testing—whether for electric vehicles, consumer electronics, or industrial systems—demands strict safety protocols. One often overlooked but critical element in test chamber safety is the door switch interlock system. This simple yet powerful mechanism helps prevent injuries, equipment damage, and test data corruption. In this article, […]

integration of arbin instruments with gamry potentiostats for high frequency eis up to 2 mhz copy

Integration of Arbin Instruments with Gamry Potentiostats for High-Frequency EIS up to 2 MHz

By Arbin Team | September 8, 2025

According to the standard specifications published by Arbin, integrating a Gamry device with an Arbin system typically limits the device’s original frequency capability from 2 MHz down to 100 kHz. However, in this article, we will introduce a solution that allows the system to retain the full 2 MHz frequency, with some trade-offs […]

use CC control type in MITS software to implement the above schedule

How to perform Internal Resistance measurement according to IEC 61960 with Arbin?

By Arbin Team | August 17, 2025

IR measurement is crucial to have an insight into a battery. There are many way, i.e. many standard to measure battery’s IR. This article will introduce IEC 61960 standard and how to implement it using Arbin’s equipments. IEC 61960 standard for battery IR: In this standard, a discharge pulse of […]

Figure 3: Accuracy Contour Plot

Integrated Electrochemical Impedance Spectroscopy (EIS) With Arbin Charge/Discharge Channels

By Arbin Team | August 6, 2025

Introduction Electrochemical Impedance Spectroscopy (EIS) is a foundational diagnostic technique for evaluating battery health, internal resistance, degradation mechanisms, and electrochemical behavior over time. However, EIS is traditionally limited by hardware complexity and high per-channel cost, making it difficult to scale across large battery test systems. To address these challenges, Arbin […]

How to test Protection Circuit Module

How to Test a Protection Circuit Module (PCM) Using ARBIN EOL

By Arbin Team | July 23, 2025

I. Purpose and Scope: The Protection Circuit Module (PCM) is a critical electronic component responsible for monitoring and protecting devices across a wide range of applications—from small consumer electronics to large-scale industrial equipment. Its core function is to ensure battery and device safety by preventing hazardous conditions such as overcharging, […]

Auxiliary Voltage Measurement

By Arbin Team | July 17, 2025

Introduction The Arbin Auxiliary Voltage Input Module enables precise, high-resolution voltage monitoring for battery testing applications that require measurements beyond the standard I/V channels. Typical use cases include monitoring individual cell or module voltages within a larger pack, measuring reference electrodes in three-electrode cells, or comparing BMS data with directly […]

Auxiliary Temperature Measurement example

Auxiliary Temperature Measurement

By Arbin Team | July 9, 2025

Introduction Battery temperature measurement is essential for evaluating safety, longevity, and performance in modern testing environments. Arbin supports three primary sensor technologies—thermocouples (Type T and K), RTDs (PT100), and thermistors (10kΩ)—each available through dedicated auxiliary input modules. These sensors enable precise temperature control, monitoring, and safety logic throughout battery R&D […]

Constant-C-rate w.r.t. actual capacity, rather than constant current with Arbin cyclers

By Tung Trinh | June 30, 2025

As we all know, the batteries’ capacity degrade by cycle of charge and discharge. If we set the charge and discharge current of a fixed value, such as 1A, 2A,… the length of each cycle will gradually decreases, simply because the battery’s capacity decreases: Cycle time = (Charge Capacity + […]

Example data log showing no recorded measurements during pause step while waiting for synchronization

Synchronize different battery charge/discharge channels in one environmental temperature chamber

By Arbin Team | June 17, 2025

MTCI Introduction  Arbin’s MTCI (Multi-Temperature Chamber Interface) module offers seamless and sophisticated integration with third-party environmental chambers, enabling direct control of temperature and humidity setpoints from within the Arbin test schedule. This streamlined setup allows test engineers to program and adjust environmental conditions alongside electrical cycling parameters, eliminating the need […]

Formula and variables used in Arbin MITS software for flexible battery testing

By Khoa Tran | June 10, 2025

General Description: – Software allows the user to control a test using variables rather than concrete control values (for example, instead of using 4.2V for control, the system can use “Last Step Maximum Voltage” as the control type for the following step. – It is also possible to use these […]

Battery multiple points temperature measurement

By Toan Nguyen | June 3, 2025

Importance of Temperature Monitoring in Battery Testing Accurate temperature monitoring is a critical aspect of battery testing to ensure both safety and data integrity. One key application is the prevention of thermal runaway or overheating during test procedures. When a battery exceeds a predefined temperature threshold, the test must be […]

How to detect NiMH battery fully charged status

By Arbin Team | May 26, 2025

Voltage, Temperature, and Delta-V: Indicators of Full Charge in NiMH Cells The Nickel-Metal Hydride (NiMH) battery is a type of rechargeable battery that uses nickel oxide hydroxide (NiOOH) as the positive electrode (cathode) and a hydrogen-absorbing alloy as the negative electrode (anode). Compared to nickel-cadmium (NiCd) batteries, NiMH batteries offer […]

Battery Test for Electric Vehicles (EV) Application Notes

By Arbin Team | May 23, 2025

Purpose and Applicability: This application notes introduce a series of tests for evaluating the performance of life behavior of batteries for electric vehicles (EV).Arbin works with electric vehicle industry leaders around the world, and provides a comprehensive battery test solution for cells, modules, and packs of all sizes.These tests can […]

Turnkey Battery Testing

By Arbin Team | August 27, 2024

LBTS-TC: Arbin’s Turnkey Battery Testing All-In-One Cell Testing with integrated test channels, temperature chambers, and cell holders. Precision: 100ppm measurement with industry-leading 24-bit resolution across four current ranges per test channel Turn-Key Solution, arrives fully integrated with channel and temperature cables interconnected from channel to MZTC Dynamic Temperature Setpoints managed […]

Honeywell and Arbin Instruments Team Up to Revolutionize Large Scale Lithium-Ion Battery Manufacturing

By Arbin Team | September 7, 2023

Honeywell today enhanced its Battery Manufacturing Excellence Platform (MXP) for lithium-ion battery manufacturers and gigafactories through a collaboration with Arbin Instruments to integrate an advanced autonomous formation system.

Ambri Selects Arbin Instruments’ Battery Test Equipment for Expansion of Next Generation Development Lab 

By Arbin Team | September 7, 2022

Arbin Instruments, a leader in battery testing instrumentation, has been selected by Ambri to provide high current battery testing systems for its pilot manufacturing expansion. These systems will facilitate the development and commercialization of its revolutionary Liquid Metal™ batteries. Ambri’s next-generation batteries offer long-duration stationary energy storage for a variety […]

Avoiding BMS Damage During a Sudden Disconnect Event

By Arbin Team | May 27, 2022

Arbin Instruments offers two features that, especially when applied together, can minimize the risks associated with the sudden disconnect of a battery mid-test.

Tesla Gigafactory

Europe’s Electric Expansion: The Rise of Gigafactories and Arbin’s Response

By Arbin Team | March 14, 2022

As part of our aim to support those moving the battery industry forward, Arbin Instruments is committed to battery development in Europe. Arbin is working to address the increasing demand for battery research and production in two key ways: cycler and data management solutions for larger operations and a dedicated, growing Arbin Europe team.

Arbin CAN: BMS-to-Tester Communication with Arbin’s CAN Bus Capability

By Arbin Team | March 10, 2022

Arbin’s Mits Pro employs the CAN Bus protocol, allowing CAN messages to be sent and received between the battery test equipment and the Battery Management System, and allows external control of the Arbin tester.

Scroll to Top