Home  ›  Auxiliary Modules
Arbin auxiliary modules for battery testers

Auxiliary inputs and outputs for battery testing

Auxiliary Modules: Add Measurement, Safety and Control to Any Arbin Tester

Auxiliary modules give an Arbin battery tester extra inputs and outputs: temperature, voltage and pressure readings, CAN Bus and SMBus communication, chamber control, and analog and digital I/O. Order them with a new system or add them to a tester you already own.

How auxiliaries work

The tester charges and discharges the battery. Auxiliary modules bring every other signal in the test into the same schedule and the same data file.

Arbin battery tester connected to an auxiliary chassis and control computer over Ethernet
The auxiliary chassis sits beside the tester and connects over Ethernet (TCP/IP).
1

Choose the inputs and outputs

Pick the modules the test needs: temperature, voltage, pressure, CAN Bus, SMBus, chamber control, analog or digital I/O. Module types can be mixed.

2

Connect to the tester

The modules are housed in an auxiliary chassis that connects over Ethernet. It is air-cooled, runs from a 100 to 240 VAC outlet and needs no cooling infrastructure.

3

Use the signals in the test schedule

In MITS, each auxiliary channel is mapped to a test channel. Its value is logged with current and voltage, and can end a step, trigger a safety limit or drive an external device.

Measure more than current and voltage

Extra measurement channels, recorded alongside the tester data.

Temperature inputs

Thermocouple, PT100 and thermistor inputs for cell surface, tab and chamber temperatures. Each reading can be logged, used to end a test step, or set as a safety limit.

  • Sensor typesT and K thermocouple, PT100, 10 kΩ thermistor
  • Module accuracy±0.1 °C PT100, ±1 °C thermocouple
  • Widest range−200 to 1,200 °C (K-type)

Voltage inputs

Extra voltage sense channels for reference electrodes in three-electrode cells, or for individual cell and module voltages inside a pack.

  • Ranges±5, ±10, ±25, ±50, ±100 V
  • Accuracy±0.05% FSR
  • Resolution24-bit
  • Common modeUp to 500 V

Pressure inputs

Inputs for millivolt-output pressure transducers. Used for pouch cell swelling and for internal pressure in cylindrical and prismatic cells.

  • Sensor signal0 to 10 mV or 0 to 100 mV
  • Accuracy±0.1% FSR
  • Sensor supply15 V, built in

Communicate with and control other equipment

Connect the tester to the BMS, the temperature chamber and the rest of the test setup.

CAN Bus

Reads messages from a battery management system and sends messages to it. BMS values such as state of charge, temperature and fault flags can be logged and used to control or stop the test.

  • ProtocolsCAN 2.0 and CAN FD
  • Identifiers11-bit or 29-bit
  • Baud rate125k to 1M
  • SetupDBC file import

SMBus

Reads and writes the registers of a smart battery during a test. Register values are logged with the tester data and can control or limit the test.

  • ProtocolsSMBus 1.1 and 2.0
  • Clock speed10 to 100 kHz
  • FitOne SMBus input per test channel

Chamber interface (MTCI)

Lets the test schedule set the temperature of a third-party chamber and wait for it before the next step. Chamber readings are logged with the cell data.

  • ConnectionRS-232
  • ControlsTemperature, and humidity where the chamber supports it
  • FitOne interface per chamber

Analog I/O

Analog signals for flow controllers, pumps, regulators and valves, with open-loop or closed-loop (PID) control from the test schedule.

  • Output−10 to 10 V
  • Option4 to 20 mA current mode
  • Accuracy±0.1% FSR

Digital I/O

Switched inputs and outputs that connect the tester to interlocks, emergency stops, alarms, fans and PLCs.

  • TypesRelay or TTL (0 to 5 V)
  • Relay outputUp to 30 V, 1 A

Tell us the signals in your test

Send the tester model and what you need to measure or control. We will recommend the modules and send the auxiliary catalog.

Request the Catalog

What you can do with auxiliaries

Measurement

Record the signals that explain the test result.

  • ✓Reference electrode voltage in three-electrode cells
  • ✓Cell and module voltages inside a pack
  • ✓Cell surface and chamber temperature
  • ✓Pouch cell swelling and internal cell pressure
  • ✓BMS readings compared with direct measurements

Safety

Let the test react before a problem grows.

  • ✓Temperature limits that stop a channel
  • ✓Pressure limits that stop a channel
  • ✓Door interlocks and emergency stops through digital inputs
  • ✓Alarms and fans switched by relay outputs
  • ✓BMS fault flags read over CAN Bus

Control

Run the whole setup from one test schedule.

  • ✓Chamber temperature set step by step
  • ✓Test steps that wait for the chamber to reach temperature
  • ✓Messages sent to the BMS over CAN Bus
  • ✓Pumps, valves and flow controllers, for example on flow batteries
  • ✓Signals exchanged with PLCs and automation

Specifications at a glance

Headline figures for each module type. The auxiliary catalog has the full specifications.

ModuleSignalRangeAccuracy or detail
Temperature, thermocoupleType T or Type K−270 to 400 °C (T), −200 to 1,200 °C (K)±1 °C
Temperature, PT100PT100 RTD−50 to 200 °C±0.1 °C
Temperature, thermistor10 kΩ thermistor−80 to 150 °C±0.2 °C
VoltageIsolated voltage input±5, ±10, ±25, ±50 or ±100 V±0.05% FSR, 24-bit, common mode up to 500 V
PressureMillivolt-output transducer0 to 10 mV or 0 to 100 mV±0.1% FSR, 15 V sensor supply
CAN BusCAN 2.0 and CAN FD125k, 250k, 500k or 1M baud11-bit or 29-bit identifiers, DBC file import
SMBusSMBus 1.1 and 2.010 to 100 kHz clockRead and write registers
Chamber interface (MTCI)RS-232One chamber per interfaceTemperature, and humidity where the chamber supports it
Analog I/OVoltage, or current as an option−10 to 10 V, or 4 to 20 mA±0.1% FSR, ±40 µA in current mode
Digital I/ORelay or TTLRelay output up to 30 V, 1 ATTL at 0 to 5 V logic

Temperature ranges and accuracies are for the module. The sensor may have a narrower range and adds its own tolerance. Compatible chamber controllers for the chamber interface are listed on request. Specifications are subject to change.

Add them now or later

Auxiliaries do not have to be decided on day one. Start with the channels you need today and add inputs and outputs when the test plan changes.

  • ✓Ordered with a new tester, auxiliaries arrive configured and ready to use.
  • ✓Added later, they connect to the tester you already have over Ethernet.
  • ✓Arbin support enables the new channels in MITS by remote session.
  • ✓Tell us the tester model and the signals you need, and we will match the right hardware.

Tell us what you need to measure or control

Send us your tester model and the signals in your test. We will reply with the auxiliary catalog and a recommendation.