部署Arbin系统是否有特定的场地准备要求?

作者:Arbin Team | 2026年5月8日

Generally, there are several points to note: Arbin machines typically have a working ambient temperature range of 0°C to 30°C. Therefore, please prepare the air-conditioning system accordingly. The power grid system must be prepared to match the machine’s input power requirements. For example, some machines require single-phase power input, while […]

我能自己设置Arbin系统的硬件和软件吗,还是需要Arbin的协助?

作者:Arbin Team | 2026年5月8日

Arbin systems will be shipped with a computer that includes the full software kit pre-installed. The system hardware setup is simple: customers can easily set it up themselves by connecting the cycler to the computer and auxiliary devices using Ethernet cables. Figure 1: Example TCP/IP Connection to Arbin Main System […]

购买 Arbin 机器接受哪些付款方式?

作者:Arbin Team | 2026年5月8日

Normal bank wire transfer is preferred. We avoid LC. Arbin’s standard payment mode is 40% – 40% – 20%. The first 40% is due right after the PO is received. Production starts only after Arbin’s bank account receives this payment. Lead time counts from this moment, not from PO receipt. […]

启动测试时出现”Conflict Clamp V”弹窗

作者:Arbin Team | 2026年5月8日

This error occurs only when the Channel Based Voltage Clamp option is unchecked in ArbinAdvSys.cfg. This means all IV channels on the same IV channel board share one voltage clamp/voltage check. The MITS software must ensure all schedules on the same IV board channels share the same Voltage Clamp setting; […]

我的测试因“Aux CAN Lost”或”Aux ACK Failed”错误而停止”

作者:Arbin Team | 2026年5月8日

This error means the Aux channel lost communication with IV channels. It usually occurs when the Batch/Mapping file was created or modified without downloading it to the cycler. Downloading the Batch/Mapping file resolves this issue: If this does not resolve the issue, check the cable connection from the Aux module […]

测试是否需要在温度室、安全室或手套箱中进行?

作者:Arbin Team | 2026年5月8日

Installing a battery inside the chambers or glovebox is optional, Arbin can integrate it if customers need it for testing. Arbin offers an 8-zone temperature chamber for battery testing (MZTC) with an operating temperature of 10-60C and for cells rated up to 60A. Connections are made easy with the cables […]

被测设备(电池单元、模块或电池组)将如何连接到 Arbin 系统?

作者:Arbin Team | 2026年5月8日

There are several way to connect to the DUT as follows: Individual cables Individual cell holders (coin cells, cylindrical cells, flat/pouch cells) Trays for holding multiple cells (coin cells, cylindrical cells, flat/pouch cells) Racks for organizing cells Chambers We will go to each method one by one as follows: 1. […]

我的测试由于一个名为“IR Inf”的错误而停止”

作者:Arbin Team | 2026年5月6日

The “IR Inf” error occurs when the system fails to obtain a valid result during an Internal Resistance (IR) measurement step. This typically happens when the measurement conditions are not sufficient to produce a reliable calculation, causing the system to return an infinite (invalid) resistance value and stop the test. […]

我有多台不同品牌的恒温恒湿箱,能买一台MTCI设备,然后在这些箱子之间轮换使用吗?

作者:Arbin Team | 2026年5月6日

The answer is yes and no. Yes, if those chambers use the same communication protocol. For example, Votsch VT4002 and Weiss WT20/40 use the Votsch L4006 protocol. If you have these two chambers, you only need one MTCI unit. However, if you have another chamber like Espec SU-241 that uses […]

Arbin 软件能否生成跨周期、跨一个或多个通道的数据对比图?

作者:Arbin Team | 2026年5月6日

Yes. Arbin Data Watcher software (Version 2.2.217 and later) can do this. In Data Watcher software, click “Edit Chart Template”. From the Model dropdown, select “CycleCompare”. Return to the main window of Data Watcher. In the axis configuration, you can select the physical quantity for the X, Y1, and Y2 […]

步控错误检查不安全

作者:Arbin Team | 2026年5月6日

The “Step Control Error Check Unsafe” warning indicates that the system has detected a significant deviation between the expected (configured) output and the actual measured output during a test step. They are designed to detect open circuits or short circuits caused by loose IV cable connections, it also detects abnormal […]

充电/放电电流几乎为0或远远小于设定值?

作者:Toan Nguyen | 2026年5月3日

In some cases, the charge or discharge current may be significantly lower than the configured value, or even close to zero. This issue is typically caused by software configuration limits or hardware-related problems. This article provides a structured troubleshooting guide to help identify and resolve the issue efficiently. Symptoms You […]

Solar & Storage Live Malaysia 2026: Advancing Battery Innovation for a Sustainable Energy Future

作者:Arbin Team | 4月 12, 2026

Event Overview Solar & Storage Live Malaysia 2026 is a premier event in Southeast Asia dedicated to solar energy and energy storage technologies. Taking place on April 8–9, 2026 at MITEC in Kuala Lumpur, the exhibition gathers industry leaders, engineers, and innovators across the global energy ecosystem. Organized by Terrapinn, […]

我的测试因“Tokenbroken”错误而停止”

作者:Arbin Team | 2026年4月9日

This error indicates too much data logged at a very short period of time. Check the schedule, make sure the data log setting is appropriate. Please open the schedule and locate the Log Limit: Then check the following points: Logging interval (time between data points)Many Arbin machines can acquire data […]

我明明已经映射了辅助值,为什么看不到呢?

作者:Arbin Team | 2026年4月5日

In some cases, users may successfully configure (map) an auxiliary channel, but the corresponding auxiliary values do not appear during test execution. This issue is typically caused by missing schedule assignment or incomplete auxiliary channel configuration within the schedule. Possible Causes No schedule or an incorrect schedule is assigned to […]

为什么我的日程开始后会立即停止?

作者:Arbin Team | 2026年4月2日

In some situations, a schedule may stop immediately after it starts. This behavior usually occurs when certain safety conditions are not met or when required devices are not properly connected. The system automatically stops the schedule to prevent unexpected behavior, hardware damage, or unsafe operating conditions. This article provides common […]

Arbin Participates in International Battery Seminar & Exhibit 2026 as Corporate Sponsor

作者:Arbin Team | 3月 31, 2026

Arbin Instruments recently participated in the International Battery Seminar and Exhibit 2026 in Orlando, Florida—one of the industry’s most established events focused on battery technology and energy storage innovation. As a proud Corporate-level sponsor, Arbin was honored to support this premier gathering of researchers, engineers, and industry leaders from across […]

Arbin Showcases Advanced Battery Testing Solutions at The Battery Show Asia 2026 in Hong Kong

作者:Arbin Team | 3月 13, 2026

Arbin Instruments proudly participated in The Battery Show Asia 2026, one of the region’s most influential exhibitions for advanced battery technology, energy storage, and electric mobility. The event was held at AsiaWorld‑Expo in Hong Kong, bringing together leading companies, engineers, and innovators from across the global battery ecosystem. As both […]

Arbin to Showcase Advanced Battery Testing Solutions at InterBattery 2026 in Seoul

作者:Arbin Team | 3月 13, 2026

Arbin Instruments is pleased to announce its participation in InterBattery 2026, one of the world’s leading exhibitions dedicated to battery technology and energy storage innovation. The event takes place March 11–13, 2026, at COEX Convention & Exhibition Center in Seoul, South Korea. As Korea’s largest international battery exhibition, InterBattery brings […]

用户自定义元变量(MV_UD)的应用示例

作者:Arbin Team | 2026年2月26日

In Arbin software, MV_UD (short for User-Defined Meta Variables) is a powerful tool for controlling battery testers. This article explains how to use MV_UD in Arbin MITS software. Storing Values in MV_UD with SetValue(s) In the Control Type list, select SetValue(s). SetValue(s) assigns a fixed value of a physical quantity […]