{"id":205661,"date":"2026-11-20T02:16:05","date_gmt":"2026-11-20T08:16:05","guid":{"rendered":"https:\/\/www.arbin.com\/?p=205661"},"modified":"2026-11-20T02:16:05","modified_gmt":"2026-11-20T08:16:05","slug":"what-is-calibration-interval","status":"publish","type":"post","link":"https:\/\/www.arbin.com\/zh\/what-is-calibration-interval.html","title":{"rendered":"What is calibration interval?"},"content":{"rendered":"<p data-renderer-start-pos=\"1\" data-local-id=\"cc36711c6d95\"><strong data-renderer-mark=\"true\">Short answer:<\/strong> A calibration interval is the planned time between two calibrations of an instrument. In other words, it\u2019s how long you can rely on the last calibration before the system needs to be calibrated again. For Arbin battery test systems, Arbin recommends a <strong data-renderer-mark=\"true\">12-month (annual)<\/strong> calibration interval.<\/p>\n<div class=\"_3iDTPbvLZJ renderer-heading-wrapper\" data-testid=\"renderer-heading-wrapper\" data-level=\"3\">\n<h2 id=\"Why-does-the-calibration-interval-matter?\" tabindex=\"-1\" data-local-id=\"58134111411c\" data-renderer-start-pos=\"310\">Why does the calibration interval matter?<\/h2>\n<\/div>\n<p data-renderer-start-pos=\"353\" data-local-id=\"b60e8d0263b3\">All measuring instruments drift over time. In a battery test system, precision parts such as current shunts, voltage references and A\/D converters change slowly. Age, heating and cooling during normal operation, and knocks from moving or shipping the system all add to this drift. Calibrating at a regular interval:<\/p>\n<ul class=\"ak-ul\" data-local-id=\"002a0b2c-4cbc-4802-b321-102fc317dbe2\" data-indent-level=\"1\">\n<li>\n<p data-renderer-start-pos=\"672\" data-local-id=\"1cf6571f2000\">Checks that the system still meets its published voltage and current accuracy, and corrects any drift<\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"777\" data-local-id=\"7af99262bac6\">Keeps your results reliable: capacity, energy, coulombic efficiency, <span data-highlighted=\"true\" data-vc=\"highlighted-text\"><span class=\"_1mT5xdRAKS\"><span class=\"_0nmozVaHVx _2V7sgO2M4S _3BoeIDwZ7G _30zrXRyxdf _0ReiIH7zJH\" data-testid=\"definition-highlighter\">DCIR<\/span><\/span><\/span> and more<\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"863\" data-local-id=\"70f48c86efd4\">Keeps measurements traceable to national standards (e.g., <span data-highlighted=\"true\" data-vc=\"highlighted-text\"><span class=\"_1mT5xdRAKS\"><span class=\"_0nmozVaHVx _2V7sgO2M4S _3BoeIDwZ7G _30zrXRyxdf _0ReiIH7zJH\" data-testid=\"definition-highlighter\">NIST<\/span><\/span><\/span>)<\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"930\" data-local-id=\"83939f600fb8\">Gives you the calibration records auditors expect under ISO 9001, ISO\/<span data-highlighted=\"true\" data-vc=\"highlighted-text\"><span class=\"_1mT5xdRAKS\"><span class=\"_0nmozVaHVx _2V7sgO2M4S _3BoeIDwZ7G _30zrXRyxdf _0ReiIH7zJH\" data-testid=\"definition-highlighter\">IEC<\/span><\/span><\/span> 17025, <span data-highlighted=\"true\" data-vc=\"highlighted-text\"><span class=\"_1mT5xdRAKS\"><span class=\"_0nmozVaHVx _2V7sgO2M4S _3BoeIDwZ7G _30zrXRyxdf _0ReiIH7zJH\" data-testid=\"definition-highlighter\">IATF<\/span><\/span><\/span> 16949 and similar quality systems<\/p>\n<\/li>\n<\/ul>\n<div class=\"_3iDTPbvLZJ renderer-heading-wrapper\" data-testid=\"renderer-heading-wrapper\" data-level=\"3\">\n<h2 id=\"Key-terms\" tabindex=\"-1\" data-local-id=\"910382fd454e\" data-renderer-start-pos=\"1053\">Key terms<\/h2>\n<\/div>\n<div class=\"pm-table-container with-shadow-observer\" data-layout=\"custom\" data-testid=\"table-container\">\n<div class=\"pm-table-wrapper\" data-number-column=\"false\" data-layout=\"default\" data-autosize=\"false\" data-table-local-id=\"6e4d8d76-5dd2-4243-a26b-88eda52dd247\" data-table-width=\"760\" data-vc=\"table-node-wrapper\">\n<div class=\"sentinel-left\"><\/div>\n<table data-testid=\"renderer-table\" data-number-column=\"false\" data-table-width=\"760\" data-layout=\"default\">\n<colgroup><\/colgroup>\n<tbody>\n<tr>\n<th class=\"ak-renderer-tableHeader-sortable-column__wrapper\" colspan=\"1\" rowspan=\"1\" data-reaches-top=\"true\" data-reaches-left=\"true\" aria-sort=\"none\">\n<div class=\"ak-renderer-tableHeader-sortable-column\">\n<p data-renderer-start-pos=\"1067\" data-local-id=\"891941be5778\">Term<\/p>\n<figure class=\"ak-renderer-tableHeader-sorting-icon__wrapper ak-renderer-tableHeader-sorting-icon__no-order\">\n<div role=\"presentation\">\n<div class=\"ak-renderer-tableHeader-sorting-icon css-19uwmmu\" tabindex=\"0\" role=\"button\" aria-label=\"\u6ca1\u6709\u5bf9\u5217\u8fdb\u884c\u6392\u5e8f\" aria-disabled=\"false\" aria-hidden=\"false\">\n<div class=\"_23rrnHAAU9 _39xV02ey7F _0jFU0Vey7F _3iDTPbQ4SZ _37wbyuDIqT _0hPCNLDIqT _0yKXXaP6LB _1YKVNsVpNL\"><\/div>\n<\/div>\n<\/div>\n<\/figure>\n<\/div>\n<\/th>\n<th class=\"ak-renderer-tableHeader-sortable-column__wrapper\" colspan=\"1\" rowspan=\"1\" data-reaches-top=\"true\" data-reaches-right=\"true\" aria-sort=\"none\">\n<div class=\"ak-renderer-tableHeader-sortable-column\">\n<p data-renderer-start-pos=\"1075\" data-local-id=\"3d598af932c6\">Meaning<\/p>\n<figure class=\"ak-renderer-tableHeader-sorting-icon__wrapper ak-renderer-tableHeader-sorting-icon__no-order\">\n<div role=\"presentation\">\n<div class=\"ak-renderer-tableHeader-sorting-icon css-19uwmmu\" tabindex=\"0\" role=\"button\" aria-label=\"\u6ca1\u6709\u5bf9\u5217\u8fdb\u884c\u6392\u5e8f\" aria-disabled=\"false\" aria-hidden=\"false\">\n<div class=\"_23rrnHAAU9 _39xV02ey7F _0jFU0Vey7F _3iDTPbQ4SZ _37wbyuDIqT _0hPCNLDIqT _0yKXXaP6LB _1YKVNsVpNL\"><\/div>\n<\/div>\n<\/div>\n<\/figure>\n<\/div>\n<\/th>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" data-reaches-left=\"true\">\n<p data-renderer-start-pos=\"1088\" data-local-id=\"eb5ec405374d\">\u6821\u51c6<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" data-reaches-right=\"true\">\n<p data-renderer-start-pos=\"1103\" data-local-id=\"c74fb0e1233b\">Comparing the system\u2019s readings with a traceable reference standard and adjusting the system if needed<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" data-reaches-left=\"true\">\n<p data-renderer-start-pos=\"1211\" data-local-id=\"0ca344855a80\">Calibration interval<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" data-reaches-right=\"true\">\n<p data-renderer-start-pos=\"1235\" data-local-id=\"5fa306a49db2\">The time allowed between two calibrations (12 months recommended for Arbin systems)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" data-reaches-left=\"true\">\n<p data-renderer-start-pos=\"1324\" data-local-id=\"224a6247f433\">Calibration due date<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" data-reaches-right=\"true\">\n<p data-renderer-start-pos=\"1348\" data-local-id=\"348bcf6f7bf9\">Date of the last calibration + the calibration interval<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" data-reaches-bottom=\"true\" data-reaches-left=\"true\">\n<p data-renderer-start-pos=\"1409\" data-local-id=\"4e8f07a48d7c\">Overdue<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" data-reaches-bottom=\"true\" data-reaches-right=\"true\">\n<p data-renderer-start-pos=\"1420\" data-local-id=\"bd71ac500828\">The due date has passed, so the system\u2019s accuracy is no longer verified<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sentinel-right\"><\/div>\n<\/div>\n<\/div>\n<p data-renderer-start-pos=\"1496\" data-local-id=\"bd6a9c2f1c91\"><strong data-renderer-mark=\"true\">Example:<\/strong> A system calibrated on 15 March 2026 with a 12-month interval is due for its next calibration by 15 March 2027.<\/p>\n<div class=\"_3iDTPbvLZJ renderer-heading-wrapper\" data-testid=\"renderer-heading-wrapper\" data-level=\"3\">\n<h2 id=\"When-should-I-calibrate-sooner?\" tabindex=\"-1\" data-local-id=\"945c93e3c066\" data-renderer-start-pos=\"1618\">When should I calibrate sooner?<\/h2>\n<\/div>\n<p data-renderer-start-pos=\"1651\" data-local-id=\"8642909b54e2\">A 12-month interval suits typical lab use. Consider calibrating earlier, or using a shorter interval, if:<\/p>\n<ul class=\"ak-ul\" data-local-id=\"a1e7f1ab-8110-4a7f-8142-5a71740d15df\" data-indent-level=\"1\">\n<li>\n<p data-renderer-start-pos=\"1760\" data-local-id=\"cac05dc5c5eb\">The system runs nonstop (24\/7) or often at high current<\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"1819\" data-local-id=\"c6fd2457254e\">The lab has large temperature swings, high humidity, dust or a corrosive atmosphere<\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"1906\" data-local-id=\"e294c00cc4fe\">The system has been moved or shipped<\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"1946\" data-local-id=\"cf9ed7af4111\">Hardware has been repaired or replaced (e.g., a channel board)<\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"2012\" data-local-id=\"40ce086be933\">Something abnormal happened, such as a power surge, short circuit, \u2026<\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"2084\" data-local-id=\"1557fbe35ee4\">Readings disagree with a reference meter or with other channels<\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"2151\" data-local-id=\"342cce12dd9b\">Your application, quality system or customer contract needs tighter control (e.g., high-precision coulombic efficiency testing)<\/p>\n<\/li>\n<\/ul>\n<div class=\"_3iDTPbvLZJ renderer-heading-wrapper\" data-testid=\"renderer-heading-wrapper\" data-level=\"3\">\n<h2 id=\"Can-the-interval-be-longer-than-12-months?\" tabindex=\"-1\" data-local-id=\"0177af7317ae\" data-renderer-start-pos=\"2282\">Can the interval be longer than 12 months?<\/h2>\n<\/div>\n<p data-renderer-start-pos=\"2326\" data-local-id=\"5b1989384400\">Your organization makes the final decision. For best performance, Arbin still recommends 12 months.<\/p>\n<div class=\"_3iDTPbvLZJ renderer-heading-wrapper\" data-testid=\"renderer-heading-wrapper\" data-level=\"3\">\n<h2 id=\"What-if-my-system-is-overdue?\" tabindex=\"-1\" data-local-id=\"4979a44a8c52\" data-renderer-start-pos=\"2427\">What if my system is overdue?<\/h2>\n<\/div>\n<p data-renderer-start-pos=\"2458\" data-local-id=\"f7e3aa3f8983\">An overdue system isn\u2019t necessarily inaccurate, but its accuracy can no longer be confirmed. Data collected after the due date may be questioned in audits, customer reviews or publications. Schedule a calibration as soon as possible. If the calibration finds a channel out of tolerance, check whether tests run on that channel since the previous calibration could be affected.<\/p>\n<div class=\"_3iDTPbvLZJ renderer-heading-wrapper\" data-testid=\"renderer-heading-wrapper\" data-level=\"3\">\n<h2 id=\"How-do-I-schedule-a-calibration?\" tabindex=\"-1\" data-local-id=\"8d1302c06ce0\" data-renderer-start-pos=\"2836\">How do I schedule a calibration?<\/h2>\n<\/div>\n<p data-renderer-start-pos=\"2870\" data-local-id=\"aa37a43be50d\">You have 2 options:<\/p>\n<ul class=\"ak-ul\" data-local-id=\"4c5e2238-a035-4ed1-87bd-3b8cc810a1ae\" data-indent-level=\"1\">\n<li>\n<p data-renderer-start-pos=\"2893\" data-local-id=\"ba70c29e5a6e\"><strong data-renderer-mark=\"true\">On-site calibration by Arbin:<\/strong> Arbin service engineers calibrate your system at your facility. Arbin recommends this for the annual calibration.<\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"3040\" data-local-id=\"237971ed0c5e\"><strong data-renderer-mark=\"true\">Rent an Arbin Auto-Calibration Box:<\/strong> Calibrate your system yourself, on your own schedule. This also works for extra checks between annual calibrations, for example after the system is moved or repaired.<\/p>\n<\/li>\n<\/ul>\n<p data-renderer-start-pos=\"3246\" data-local-id=\"2d2eb817b87a\">For either option, contact your regional Arbin office through the <a class=\"_2hGPVj98eZ _2i3C1kYbGa _2kH23qT6kp _1ubuxonXvL _34b3D2vc3e _1NDpvb6wH8 _2wtOC9vc3e _3e11vU6wH8 _0hSAgbHZdu _00uqCY98eZ _3xtjKN0Rl6 _0H9qDF6wH8 _24h04i2Njc _1mT5xdRAKS _0bjKvDcjp5 _0WKd3G4z3T _23rrnHo10F _1UtDYzM7Tp _32C2rk98eZ _0i9AWA0Rl6 _0mm6KQ6wH8 _10n1R5M7Tp _0DCa9DjOvk _3932vv0Rl6 _02cRtH6wH8 _1B4rbIo10F _0clgaMM7Tp _3WzCGijOvk _0NqVRt0Rl6 _3BKYwu6wH8 _3sFUREDdj4 _0CMRbkAwSC _2nTuUYWfPD _3ADzdEWfPD _1warJ9WfPD _4scvAwWyeI\" title=\"https:\/\/www.arbin.com\/contacts\/\" href=\"https:\/\/www.arbin.com\/zh\/contacts\/\" data-renderer-mark=\"true\" data-is-router-link=\"false\" data-testid=\"link-with-safety\">Arbin Contact page<\/a> with your system serial number(s). Book ahead so calibration happens before your due date.<\/p>\n<p data-renderer-start-pos=\"3423\" data-local-id=\"3835c0e2ba7e\">Sources:<\/p>\n<ul class=\"ak-ul\" data-local-id=\"8fcdb11b-e64e-49ad-9435-b331e66c964d\" data-indent-level=\"1\">\n<li>\n<p data-renderer-start-pos=\"3435\" data-local-id=\"693e8267fe10\"><a class=\"_2hGPVj98eZ _2i3C1kYbGa _2kH23qT6kp _1ubuxonXvL _34b3D2vc3e _1NDpvb6wH8 _2wtOC9vc3e _3e11vU6wH8 _0hSAgbHZdu _00uqCY98eZ _3xtjKN0Rl6 _0H9qDF6wH8 _24h04i2Njc _1mT5xdRAKS _0bjKvDcjp5 _0WKd3G4z3T _23rrnHo10F _1UtDYzM7Tp _32C2rk98eZ _0i9AWA0Rl6 _0mm6KQ6wH8 _10n1R5M7Tp _0DCa9DjOvk _3932vv0Rl6 _02cRtH6wH8 _1B4rbIo10F _0clgaMM7Tp _3WzCGijOvk _0NqVRt0Rl6 _3BKYwu6wH8 _3sFUREDdj4 _0CMRbkAwSC _2nTuUYWfPD _3ADzdEWfPD _1warJ9WfPD _4scvAwWyeI\" title=\"https:\/\/arbin.com\/services\/\" href=\"https:\/\/www.arbin.com\/zh\/services.html\/\" data-renderer-mark=\"true\" data-is-router-link=\"false\" data-testid=\"link-with-safety\">Arbin \u2013 Services (Calibration)<\/a><\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"3469\" data-local-id=\"89f3d0c660db\"><a class=\"_2hGPVj98eZ _2i3C1kYbGa _2kH23qT6kp _1ubuxonXvL _34b3D2vc3e _1NDpvb6wH8 _2wtOC9vc3e _3e11vU6wH8 _0hSAgbHZdu _00uqCY98eZ _3xtjKN0Rl6 _0H9qDF6wH8 _24h04i2Njc _1mT5xdRAKS _0bjKvDcjp5 _0WKd3G4z3T _23rrnHo10F _1UtDYzM7Tp _32C2rk98eZ _0i9AWA0Rl6 _0mm6KQ6wH8 _10n1R5M7Tp _0DCa9DjOvk _3932vv0Rl6 _02cRtH6wH8 _1B4rbIo10F _0clgaMM7Tp _3WzCGijOvk _0NqVRt0Rl6 _3BKYwu6wH8 _3sFUREDdj4 _0CMRbkAwSC _2nTuUYWfPD _3ADzdEWfPD _1warJ9WfPD _4scvAwWyeI\" title=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/03\/iso17025.pdf\" href=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/03\/iso17025.pdf\" data-renderer-mark=\"true\" data-is-router-link=\"false\" data-testid=\"link-with-safety\">Arbin ISO\/<span data-highlighted=\"true\" data-vc=\"highlighted-text\">IEC<\/span> 17025 accreditation certificate (<span data-highlighted=\"true\" data-vc=\"highlighted-text\">PJLA<\/span>)<\/a><\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"3525\" data-local-id=\"002832a379aa\"><a class=\"_2hGPVj98eZ _2i3C1kYbGa _2kH23qT6kp _1ubuxonXvL _34b3D2vc3e _1NDpvb6wH8 _2wtOC9vc3e _3e11vU6wH8 _0hSAgbHZdu _00uqCY98eZ _3xtjKN0Rl6 _0H9qDF6wH8 _24h04i2Njc _1mT5xdRAKS _0bjKvDcjp5 _0WKd3G4z3T _23rrnHo10F _1UtDYzM7Tp _32C2rk98eZ _0i9AWA0Rl6 _0mm6KQ6wH8 _10n1R5M7Tp _0DCa9DjOvk _3932vv0Rl6 _02cRtH6wH8 _1B4rbIo10F _0clgaMM7Tp _3WzCGijOvk _0NqVRt0Rl6 _3BKYwu6wH8 _3sFUREDdj4 _0CMRbkAwSC _2nTuUYWfPD _3ADzdEWfPD _1warJ9WfPD _4scvAwWyeI\" title=\"https:\/\/www.oiml.org\/en\/files\/pdf_d\/d010-e07.pdf\" href=\"https:\/\/www.oiml.org\/en\/files\/pdf_d\/d010-e07.pdf\" data-renderer-mark=\"true\" data-is-router-link=\"false\" data-testid=\"link-with-safety\">ILAC-G24 \/ <span data-highlighted=\"true\" data-vc=\"highlighted-text\">OIML<\/span> D 10 \u2013 Guidelines for the determination of calibration intervals<\/a><\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"3609\" data-local-id=\"583534f81fdc\"><a class=\"_2hGPVj98eZ _2i3C1kYbGa _2kH23qT6kp _1ubuxonXvL _34b3D2vc3e _1NDpvb6wH8 _2wtOC9vc3e _3e11vU6wH8 _0hSAgbHZdu _00uqCY98eZ _3xtjKN0Rl6 _0H9qDF6wH8 _24h04i2Njc _1mT5xdRAKS _0bjKvDcjp5 _0WKd3G4z3T _23rrnHo10F _1UtDYzM7Tp _32C2rk98eZ _0i9AWA0Rl6 _0mm6KQ6wH8 _10n1R5M7Tp _0DCa9DjOvk _3932vv0Rl6 _02cRtH6wH8 _1B4rbIo10F _0clgaMM7Tp _3WzCGijOvk _0NqVRt0Rl6 _3BKYwu6wH8 _3sFUREDdj4 _0CMRbkAwSC _2nTuUYWfPD _3ADzdEWfPD _1warJ9WfPD _4scvAwWyeI\" title=\"https:\/\/qm-dag.pages.dev\/topics\/ISO17025\/6_4_equipment\" href=\"https:\/\/qm-dag.pages.dev\/topics\/ISO17025\/6_4_equipment\" data-renderer-mark=\"true\" data-is-router-link=\"false\" data-testid=\"link-with-safety\">ISO\/<span data-highlighted=\"true\" data-vc=\"highlighted-text\">IEC<\/span> 17025:2017 clause 6.4.7 \u2013 Calibration programme<\/a><\/p>\n<\/li>\n<li>\n<p data-renderer-start-pos=\"3668\" data-local-id=\"88ffa540860d\"><a class=\"_2hGPVj98eZ _2i3C1kYbGa _2kH23qT6kp _1ubuxonXvL _34b3D2vc3e _1NDpvb6wH8 _2wtOC9vc3e _3e11vU6wH8 _0hSAgbHZdu _00uqCY98eZ _3xtjKN0Rl6 _0H9qDF6wH8 _24h04i2Njc _1mT5xdRAKS _0bjKvDcjp5 _0WKd3G4z3T _23rrnHo10F _1UtDYzM7Tp _32C2rk98eZ _0i9AWA0Rl6 _0mm6KQ6wH8 _10n1R5M7Tp _0DCa9DjOvk _3932vv0Rl6 _02cRtH6wH8 _1B4rbIo10F _0clgaMM7Tp _3WzCGijOvk _0NqVRt0Rl6 _3BKYwu6wH8 _3sFUREDdj4 _0CMRbkAwSC _2nTuUYWfPD _3ADzdEWfPD _1warJ9WfPD _4scvAwWyeI\" title=\"https:\/\/www.electronicdesign.com\/technologies\/test-measurement\/article\/55016903\/keysight-technologies-battery-tester-calibration-benefits-and-procedure\" href=\"https:\/\/www.electronicdesign.com\/technologies\/test-measurement\/article\/55016903\/keysight-technologies-battery-tester-calibration-benefits-and-procedure\" data-renderer-mark=\"true\" data-is-router-link=\"false\" data-testid=\"link-with-safety\">Electronic Design \u2013 Benefits from Calibrating Your Battery Tester<\/a><\/p>\n<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Short answer: A calibration interval is the planned time between two calibrations of an instrument. In other words, it\u2019s how long you can rely on the last calibration before the system needs to be calibrated again. For Arbin battery test systems, Arbin recommends a 12-month (annual) calibration interval. Why does the calibration interval matter? All [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[417],"tags":[],"class_list":["post-205661","post","type-post","status-publish","format-standard","hentry","category-faq"],"acf":[],"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/posts\/205661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/comments?post=205661"}],"version-history":[{"count":1,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/posts\/205661\/revisions"}],"predecessor-version":[{"id":205662,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/posts\/205661\/revisions\/205662"}],"wp:attachment":[{"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/media?parent=205661"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/categories?post=205661"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/tags?post=205661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}