{"id":21576,"date":"2024-02-16T06:32:29","date_gmt":"2024-02-16T12:32:29","guid":{"rendered":"https:\/\/arbin.com\/?page_id=21576"},"modified":"2024-05-14T14:55:20","modified_gmt":"2024-05-14T19:55:20","slug":"lbt21-%e7%b3%bb%e5%88%97-2","status":"publish","type":"page","link":"https:\/\/www.arbin.com\/zh\/%e7%94%b5%e6%b1%a0%e6%b5%8b%e8%af%95%e8%ae%be%e5%a4%87-2\/%e7%94%b5%e6%b1%a0-%e6%b5%8b%e8%af%95-%e4%ba%a7%e5%93%81-%e7%b3%bb%e5%88%97\/rbt-cell-series.html","title":{"rendered":"RBT Cell Series"},"content":{"rendered":"<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/plugins\/bb-plugin\/img\/pixel.png\" alt=\"\" itemprop=\"image\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t<a href=\"https:\/\/arbin.com\/wp-content\/uploads\/2024\/02\/RBT-Cell_Brochure_20240223.pdf\" target=\"_blank\" rel=\"noopener\">\n\t\t\t\t\t\t\t\u4e0b\u8f7d\u578b\u5f55\u624b\u518c\n\t\t\t\t\t<\/a>\n\t<nav  aria-label=\"\u9762\u5305 \u5c51\"><ol class=\"breadcrumb\" itemscope itemtype=\"https:\/\/schema.org\/BreadcrumbList\"><li class=\"breadcrumb-item active\" aria-current=\"page\" itemprop=\"itemListElement\" itemscope itemtype=\"https:\/\/schema.org\/ListItem\"><span itemprop=\"name\">\u9996\u9875<\/span><meta itemprop=\"position\" content=\"1\"><\/li><\/ol><\/nav>\n<h1>\n\t\tRegenerative Battery Test Series for Cells (RBT-Cell)\n\t<\/h1>\n\t<table>\n<tbody>\n<tr>\n\n\n<\/tr>\n<tr>\n<td><strong>\u901a\u9053\u7535\u538b<\/strong><\/td>\n<td>6V, 10V, and 20V Models<\/td>\n<\/tr>\n<tr>\n<td><strong>\u901a\u9053\u7535\u6d41<\/strong><\/td>\n<td>\u00b1100A or \u00b1400A per channel, Up to 1,600A<\/td>\n<\/tr>\n<tr>\n<td><strong>\u901a\u9053\u6570\u91cf<\/strong><\/td>\n<td>Up to 64<\/td>\n<\/tr>\n<tr>\n\n\n<\/tr>\n<\/tbody>\n<\/table>\n\t<p>Arbin&#8217;s RBT-Cell Battery Test Series is designed to meet the growing demand for regenerative battery testing. It offers high-current, cell-level test channels that use Arbin&#8217;s regenerative technology for reliable and efficient testing and validation.<\/p>\n\t<p>As the demand for energy storage solutions grows, so does the need for regenerative technology that not only accurately tests and characterizes batteries, but also contributes to a sustainable future.<\/p>\n<p>Arbin&#8217;s Regenerative Battery Testing (<strong>RBT-Cell \u7535\u82af\u6d4b\u8bd5<\/strong>) series combines high-precision measurement and regenerative technology to reduce the overall energy cost of your testbed. This innovative technology enables researchers to generate reliable and repeatable data without compromising on results in the pursuit of energy efficiency.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/12\/Battery-Test-Lab-Rz-blue01-500x375.png\" alt=\"\u5728\u6e29\u5ea6\u5ba4\u4e2d\u6d4b\u8bd5Arbin\u7535\u6c60\u5355\u5143\" itemprop=\"image\" height=\"375\" width=\"500\" title=\"\u7535\u6c60\u6d4b\u8bd5\u5b9e\u9a8c\u5ba4 - Rz - blue01\" onerror=\"this.style.display='none'\"  \/>\n<h2>\n\t\tFlexible Configurations\n\t<\/h2>\n<table  data-tablesaw-minimap>\n\t\t\t<thead>\n\t\t<tr>\n\t\t\t<th id=\"pp-table-col-1\" scope=\"col\" data-tablesaw-sortable-col>\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\tVoltage Range Options\t\t\t\t\t\n\t\t\t\t\t<\/th><th id=\"pp-table-col-2\" scope=\"col\" data-tablesaw-sortable-col>\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\u7535\u6d41\u91cf\u7a0b\t\t\t\t\t\n\t\t\t\t\t<\/th>\t\t<\/tr>\n\t<\/thead>\n\t\t<tbody>\n\t\t<tr data-row-index=\"1\"><td>0 to 6V<\/td><td>100A\/25A or 400A\/50A<\/td><\/tr><tr data-row-index=\"2\"><td>2 to 10V<\/td><td>100\/25A or 400A\/50A<\/td><\/tr><tr data-row-index=\"3\"><td>2 to 20V<\/td><td>100A\/25A or 400A\/50A<\/td><\/tr>\t<\/tbody>\n<\/table>\n<h2>\n\t\tKey Features\n\t<\/h2>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/12\/Battery-Test-Lab-PNL-blue01.png\" alt=\"Arbin coincell battery tester in a battery test lab.\" itemprop=\"image\" height=\"450\" width=\"600\" title=\"Battery Test Lab - PNL - blue01\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t <ul><li><strong>Channel Density:<\/strong> 4 or 16 channels per module, capable of operating independently at \u00b1100A or \u00b1 400A per channel, or used in parallel to achieve current up to \u00b11,600A.\u00a0<\/li><\/ul>\t\t\n\t\t\t <ul><li><strong>Minimize Floor Space<\/strong> with up to 64 channels per rack in a compact footprint.<\/li><\/ul>\t\t\n\t\t\t <ul><li><strong>Fully parallelable<\/strong> so any number of channels on the 16-channel module can be connected to increase the current-handling capability.<\/li><\/ul>\t\t\n\t\t\t <ul><li><strong>Reduce Energy Consumption<\/strong> and HVAC load by utilizing efficient regenerative circuitry to return up to 85% of discharge energy back to the grid.<\/li><\/ul>\t\t\n\t\t\t <ul><li><strong>Reduce Energy Consumption<\/strong>: Efficient regenerative circuitry can return up to 85% of discharge energy back to the system and\/or grid.<\/li><\/ul>\t\t\n\t<h2>\n\t\tRBT-Cell Specifications\n\t<\/h2>\n<table  data-tablesaw-minimap>\n\t\t\t<thead>\n\t\t<tr>\n\t\t\t<th id=\"pp-table-col-1\" scope=\"col\" data-tablesaw-sortable-col>\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\u786c\u4ef6\u89c4\u683c\t\t\t\t\t\n\t\t\t\t\t<\/th><th id=\"pp-table-col-2\" scope=\"col\" data-tablesaw-sortable-col>\t\t\t\t\t\n\t\t\t\t\t<\/th>\t\t<\/tr>\n\t<\/thead>\n\t\t<tbody>\n\t\t<tr data-row-index=\"1\"><td>Channels per module<\/td><td>4 or 16<\/td><\/tr><tr data-row-index=\"2\"><td>\u901a\u9053\u6570 channel<\/td><td>Up to 64<\/td><\/tr><tr data-row-index=\"3\"><td>\u7535\u538b\u8303\u56f4<\/td><td>6V, 10V, or 20V<\/td><\/tr><tr data-row-index=\"4\"><td>Current per channel<\/td><td>\u00b1400A \/channel (4CH),\n\u00b1100A\/channel (16CH)<\/td><\/tr><tr data-row-index=\"5\"><td>Channel Parallel<\/td><td>Up to 16 Channels<\/td><\/tr><tr data-row-index=\"6\"><td>\u7535\u6d41\u91cf\u7a0b<\/td><td>2<\/td><\/tr><tr data-row-index=\"7\"><td>Rise Time<\/td><td>&lt;1ms for 4CH module\n&lt;2ms for 16CH module<\/td><\/tr><tr data-row-index=\"8\"><td>\u56de\u9988\u6548\u7387<\/td><td>Up to 85%<\/td><\/tr>\t<\/tbody>\n<\/table>\n<table  data-tablesaw-minimap>\n\t\t\t<thead>\n\t\t<tr>\n\t\t\t<th id=\"pp-table-col-1\" scope=\"col\" data-tablesaw-sortable-col>\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\tMeasurement Specifications\t\t\t\t\t\n\t\t\t\t\t<\/th><th id=\"pp-table-col-2\" scope=\"col\" data-tablesaw-sortable-col>\t\t\t\t\t\n\t\t\t\t\t<\/th>\t\t<\/tr>\n\t<\/thead>\n\t\t<tbody>\n\t\t<tr data-row-index=\"1\"><td>\u6d4b\u91cf\u7cbe\u5ea6<\/td><td>0.02% FSR<\/td><\/tr><tr data-row-index=\"2\"><td>\u6d4b\u91cf\u7cbe\u5ea6<\/td><td>0.01% FSR<\/td><\/tr><tr data-row-index=\"3\"><td>\u6d4b\u91cf\u5206\u8fa8\u7387<\/td><td>24 Bit<\/td><\/tr><tr data-row-index=\"4\"><td>Measurement Refresh Interval<\/td><td>2ms for 4CH module, 8ms for 16CH module<\/td><\/tr><tr data-row-index=\"5\"><td>\u65f6\u95f4\u5206\u8fa8\u7387<\/td><td>100\u03bcs<\/td><\/tr>\t<\/tbody>\n<\/table>\n<table  data-tablesaw-minimap>\n\t\t\t<thead>\n\t\t<tr>\n\t\t\t<th id=\"pp-table-col-1\" scope=\"col\" data-tablesaw-sortable-col>\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\tChassis Specifications\t\t\t\t\t\n\t\t\t\t\t<\/th><th id=\"pp-table-col-2\" scope=\"col\" data-tablesaw-sortable-col>\t\t\t\t\t\n\t\t\t\t\t<\/th>\t\t<\/tr>\n\t<\/thead>\n\t\t<tbody>\n\t\t<tr data-row-index=\"1\"><td>Cooling<\/td><td>Air<\/td><\/tr><tr data-row-index=\"2\"><td>Input Power<\/td><td>340V &#8211; 520V<\/td><\/tr><tr data-row-index=\"3\"><td>\u5e95\u76d8\u5c3a\u5bf8<\/td><td>Width: 25&#8243; \/ 635mm\nDepth: 45&#8243; \/ 1143mm\nHeight: 72&#8243; \/ 1829mm<\/td><\/tr>\t<\/tbody>\n<\/table>\n<h2>\n\t\tApplication Focus\n\t<\/h2>\n\t\t\t <ul><li><strong>Facility integration<\/strong> to interface with temperature chambers, test facilities, or other third-party systems.<\/li><\/ul>\t\t\n\t\t\t <ul><li><strong>\u7cbe\u786e\uff1a<\/strong> Each channel provides multiple current ranges with industry-leading 24-bit resolution.<\/li><\/ul>\t\t\n\t\t\t <ul><li><strong>Data Sampling and Logging:<\/strong> Powerful embedded controllers provide ultra-fast data sampling and logging.<\/li><\/ul>\t\t\n\t\t\t <ul><li><strong>Comprehensive safety features<\/strong> for lithium-ion battery testing.<\/li><\/ul>\t\t\n\t\t\t <ul><li><strong>Dynamic data acquisition<\/strong> based on changes in time, voltage, and current to capture more data when needed and maintain efficient file sizes.<\/li><\/ul>\t\t\n\t\t\t <ul><li>Simulation of Real World Test Profiles.<\/li><\/ul>\t\t\n\t\t\t <ul><li>dQdV &amp; Coulombic Efficiency.<\/li><\/ul>\t\t\n\t\t\t <ul><li>Cell-level Quality Control &amp; Grading.<\/li><\/ul>\t\t\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/08\/LBT21-SERIES_lbt21084hc-front-683x1024.png\" alt=\"LBT21-\u7cfb\u5217LBT21084HC\u524d\u89c6\u56fe\" itemprop=\"image\" height=\"1024\" width=\"683\" title=\"LBT21-SERIES_lbt21084hc-front\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/05\/engineers-working-electric-car.jpg\" alt=\"\u5973\u6027\u548c\u7537\u6027\u5de5\u7a0b\u5e08\u6b63\u5728\u8ba8\u8bba\u7535\u52a8\u6c7d\u8f66\u7684\u4e09\u7ef4CAD\u8f6f\u4ef6\u6e32\u67d3\u56fe\u3002\u5e26\u6709\u539f\u578b\u8f66\u5e95\u76d8\u7684\u9ad8\u79d1\u6280\u5b9e\u9a8c\u5ba4\u3002\" itemprop=\"image\" height=\"2880\" width=\"5120\" title=\"\u5de5\u7a0b\u5e08-\u5de5\u4f5c-\u7535\u52a8\u6c7d\u8f66\" onerror=\"this.style.display='none'\"  \/>\n<h2>\n\t\tPowerful Software Integration\n\t<\/h2>\n\t\t\t <ul><li>Create and manage test schedules, monitor real-time testing, and analyze results.<\/li><\/ul>\t\t\n\t\t\t <ul><li>Integration with third-party hardware and automation software.\u00a0\u00a0<\/li><\/ul>\t\t\n\t\t\t <ul><li>Suitable for both laboratory and production environments.<\/li><\/ul>\t\t\n\t\t\t <ul><li>Local and remote control of test channels.<\/li><\/ul>\t\t\n\t\t\t <ul><li>Test data securely stored in a range of robust database formats including MS SQL, Post GreSQL, Access, or utilize Apache Kafka for additional flexibility.\u00a0<\/li><\/ul>\t\t\n\t<h2>\n\t\t\u6d4b\u8bd5\u7cbe\u5ea6\u7684\u91cd\u8981\u6027\n\t<\/h2>\n\t<p>\u8fd9\u5f20\u56fe\u8868\u8fbe\u4e86Arbin\u7535\u6c60\u6d4b\u8bd5\u4eea\u548c\u53e6\u4e00\u4e2a\u8bbe\u5907\u5236\u9020\u5546\u4e4b\u95f4\u7684\u5dee\u5f02\u3002\u4f7f\u7528\u4e0d\u5408\u9002\u7684\u6d4b\u8bd5\u8bbe\u5907\u53ef\u80fd\u4f1a\u9519\u8fc7\u56fe\u4e0a\u4e24\u4e2a\u660e\u663e\u7684\u8dcc\u843d\u5cf0\u8c37\u3002\u4e00\u4e9b\u5382\u5bb6\u4ecd\u5728\u9500\u552e\u5341\u5e74\u4e8c\u5341\u5e74\u524d\u8bbe\u8ba1\u7684\u4ea7\u54c1\uff0c\u800cArbin\u4e00\u76f4\u5728\u52aa\u529b\u6539\u8fdb\u6211\u4eec\u7684\u8bbe\u8ba1\uff0c\u4ee5\u6ee1\u8db3\u4e0d\u65ad\u8fdb\u6b65\u7684\u884c\u4e1a\u9700\u6c42\u3002\u5728\u4e3a\u671f <strong><a href=\"https:\/\/arpa-e.energy.gov\/technologies\/projects\/ultra-precise-battery-tester\">\u4e09\u5e74\u7684ARPA-E\u9879\u76ee<\/a><\/strong> \u4e2d\uff0c\u6211\u4eec\u5f00\u53d1\u4e86\u5927\u7535\u6d41\u8d85\u9ad8\u7cbe\u5ea6\u6d4b\u8bd5\u4eea\uff0c\u5e76\u5728\u540e\u7eed\u7684\u4ea7\u54c1\u4e2d\u5e7f\u6cdb\u91c7\u7528\u4e86\u8fd9\u9879\u7814\u7a76\u4e2d\u7684\u65b0\u6280\u672f\u3002\u8fd9\u5305\u62ec\u76ee\u524d\u5728\u552e\u7684 <a href=\"https:\/\/www.arbin.com\/zh\/%e7%94%b5%e6%b1%a0%e6%b5%8b%e8%af%95%e8%ae%be%e5%a4%87-2\/%e7%94%b5%e6%b1%a0-%e6%b5%8b%e8%af%95-%e4%ba%a7%e5%93%81-%e7%b3%bb%e5%88%97\/lbt21-%e7%b3%bb%e5%88%97\/\"><strong>LBT\u7cfb\u5217<\/strong><\/a>, <a href=\"https:\/\/www.arbin.com\/zh\/?page_id=21576\"><strong>RBT-Cell \u7535\u82af\u6d4b\u8bd5<\/strong><\/a>\uff0c\u4ee5\u53ca <a href=\"https:\/\/www.arbin.com\/zh\/%e7%94%b5%e6%b1%a0%e6%b5%8b%e8%af%95%e8%ae%be%e5%a4%87-2\/%e7%94%b5%e6%b1%a0-%e6%b5%8b%e8%af%95-%e4%ba%a7%e5%93%81-%e7%b3%bb%e5%88%97\/hps-%e7%b3%bb%e5%88%97\/\"><strong>HPS<\/strong> <\/a>\u8bbe\u5907\u7cfb\u5217\u3002HPS\u8d85\u9ad8\u7cbe\u5ea6\u6d4b\u8bd5\u8bbe\u5907\u4ee3\u8868\u4e86Arbin\u6700\u9876\u5c16\u7684\u6280\u672f\u5b9e\u529b\uff0c\u53ef\u4ee5\u79f0\u4e4b\u4e3a\u884c\u4e1a\u7684\u6280\u672f\u5929\u82b1\u677f\u3002\u800c\u6211\u4eec\u7684LBT\u7cfb\u5217\u6807\u51c6\u8bbe\u5907\uff0c\u4e5f\u6bd4\u5e02\u573a\u4e0a\u7684\u5176\u4ed6\u6d4b\u8bd5\u4eea\u66f4\u5177\u5907\u6280\u672f\u4f18\u52bf\u3002<\/p>\n<p>\u5bf9\u4e8e\u957f\u671f\u7535\u6c60\u6d4b\u8bd5\u548c\u957f\u671f\u7535\u6c60\u9884\u6d4b\u6765\u8bf4\uff0c\u6d4b\u91cf\u7cbe\u5ea6\u6bd4\u5355\u7eaf\u7684\u63a7\u5236\u7cbe\u5ea6\u66f4\u4e3a\u5173\u952e\u3002\u5927\u591a\u6570\u5176\u4ed6\u7684\u7535\u6c60\u6d4b\u8bd5\u7cfb\u7edf\u6ca1\u6709\u6b63\u786e\u89c4\u5b9a\u5176\u7cbe\u5ea6\u548c\/\u6216\u7cbe\u5ea6\u76f8\u5bf9\u8f83\u5dee\uff0c\u8fd9\u963b\u788d\u4e86\u4ece\u7ed3\u679c\u6570\u636e\u4e2d\u5f97\u51fa\u7684\u7ed3\u8bba\u3002\u91cd\u8981\u7684\u8d8b\u52bf\u548c\u7535\u5316\u5b66\u6307\u6807\u53ef\u80fd\u4ecd\u7136\u6ca1\u6709\u88ab\u6ce8\u610f\u5230\uff1b\u5982\u53f3\u56fe\u6240\u793a\uff0c\u5728\u6d4b\u91cf\u566a\u97f3\u4e2d\u4e22\u5931\u3002<\/p>\n\t<strong>\u662f\u4ec0\u4e48\u5f71\u54cd\u4e86\u6d4b\u8bd5\u8bbe\u5907\u7684\u7cbe\u5ea6<\/strong><br \/>\nDAC\u7684\u5206\u8fa8\u7387<br \/>\nADC\u7684\u5206\u8fa8\u7387<br \/>\n\u6821\u51c6\u7684\u975e\u7ebf\u6027<br \/>\n\u77ed\u671f\u6f02\u79fb\uff08\u6e29\u5ea6\uff09<br \/>\n\u957f\u671f\u6f02\u79fb\uff08\u6750\u6599\u7279\u6027\uff09\n\t<b>Arbin\u6d4b\u8bd5\u8bbe\u5907\u6838\u5fc3\u6280\u672f<br \/>\n<\/b>\u66f4\u9ad8\u7684\u5206\u8fa8\u7387<br \/>\n\u6539\u8fdb\u7684\u8f6f\u4ef6\u7b97\u6cd5<br \/>\n\u70ed\u7ba1\u7406\u7684\u65b0\u65b9\u6cd5<br \/>\n\u4e13\u5229\u91c7\u6837\u7535\u963b\u8bbe\u8ba1<br \/>\n\u65b0\u7684\u6570\u636e\u65f6\u95f4\u8bb0\u5f55\u65b9\u5f0f<br \/>\n\u524d\u6cbf\u6750\u6599\u4e0e\u9ad8\u9636\u5668\u4ef6\u7684\u8fd0\u7528\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/09\/differential-capacity-graph.png\" alt=\"\u5dee\u5206\u80fd\u529b\u56fe\" itemprop=\"image\" height=\"664\" width=\"1024\" title=\"\u5dee\u5206\u80fd\u529b\u56fe\" onerror=\"this.style.display='none'\"  \/>\n<h2>\n\t\t\u53ef\u7528\u4e8e\u62d3\u5c55\u6d4b\u8bd5\u80fd\u529b\u7684\u7684\u8f85\u52a9\u6a21\u5757\u4e0e\u914d\u4ef6\n\t<\/h2>\n\t<h3>CANBus\/SMBus<\/h3>\n<p><img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/06\/CAN-500x375.jpg\" alt=\"\" width=\"500\" height=\"375\" \/><\/p>\n<p>Arbin\u63d0\u4f9b <strong>CANBus\/SMBus\u63a5\u53e3\uff0c\u00a0<\/strong>\u5141\u8bb8\u4f7f\u7528CAN\u534f\u8bae\u5bf9Arbin\u6d4b\u8bd5\u5668\u8fdb\u884c\u5b9e\u65f6\u5916\u90e8\u63a7\u5236\u3002\u8be5\u529f\u80fd\u5141\u8bb8\u7535\u6c60\u6a21\u5757\/\u7535\u6c60\u7ec4\u4e0eBMS\uff08\u7535\u6c60\u7ba1\u7406\u7cfb\u7edf\uff09\u8fdb\u884c\u901a\u4fe1\uff0c\u6216\u7528\u4e8e\u5ba2\u6237\u9700\u8981\u901a\u8fc7CAN\u8fdb\u884c\u5916\u90e8\u63a7\u5236\u7684\u7535\u6c60\u6d4b\u8bd5\u3002<\/p>\n\t<h3>MTCI<\/h3>\n<p><img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/images\/AUX-CAN-BUS_1CH_MTCI_1CH_RA_001C-500x199.png\" alt=\"CANBus MTCI\u6a21\u5757\" width=\"500\" height=\"199\" \/><\/p>\n<p>\"(\u300a\u4e16\u754c\u4eba\u6743\u5ba3\u8a00\u300b) <strong>\u6e29\u7bb1\u901a\u8baf\u63a5\u53e3\uff08MTCI\uff09<\/strong> allows the Arbin system to communicate with an approved third-party temperature\/environment chamber. Arbin&#8217;s software can turn the chamber on\/off and adjust the temperature during the test.<\/p>\n\t<h3>Battery Racks &amp; Holders<\/h3>\n<p><img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/09\/testing-pouch-cells-with-a-cycler-and-battery-rack-from-arbin-500x404.jpeg\" alt=\"\" width=\"309\" height=\"250\" \/><\/p>\n<p>\u5404\u79cd\u5939\u5177\u4e0e\u7535\u6c60\u652f\u67b6\u53ef\u7528\u4e8e\u591a\u79cd\u4e0d\u540c\u7c7b\u578b\u7684\u7535\u6c60\uff0c\u4ee5\u642d\u5efa\u6574\u6d01\u89c4\u8303\u7684\u6d4b\u8bd5\u5e73\u53f0\u3002<\/p>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-0\" data-index=\"0\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-0\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\t\u6570\u5b57\u4e0e\u6a21\u62dfI\/O\u63a5\u53e3\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-1\" data-index=\"1\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-1\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\t\u6e29\u5ea6\u63a7\u5236\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-2\" data-index=\"2\" aria-selected=\"true\" aria-controls=\"fl-tabs--panel-2\" aria-expanded=\"true\" role=\"tab\" tabindex=\"0\">\t\t\t\t\u6e29\u5ea6\u6d4b\u91cf\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-3\" data-index=\"3\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-3\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\t\u8f85\u52a9\u7535\u538b\u6d4b\u91cf\t\t\t\t<\/a>\n\t\t\t\t\t\t\u6570\u5b57\u4e0e\u6a21\u62dfI\/O\u63a5\u53e3\n\t\t\t\t\t\t\t\t\t\t\t<strong>\u6570\u5b57\u8f93\u5165\/\u8f93\u51fa\uff08Digital I\/O\uff09<\/strong> \u8fd9\u4e9b\u901a\u9053\u5141\u8bb8 Arbin \u7cfb\u7edf\u53d1\u9001\u548c\u63a5\u6536\u6570\u5b57\u7ee7\u7535\u5668\uff08\u9ad8\/\u4f4e\u3001\u5f00\/\u5173\uff09\u4fe1\u53f7\uff0c\u5e76\u4e0e\u5916\u90e8\u786c\u4ef6\u8fde\u63a5\u3002  \u5b83\u4eec\u7684\u529f\u80fd\u662f\u72ec\u7acb\u7684\uff0c\u56e0\u6b64\u7528\u6237\u53ef\u4ee5\u7075\u6d3b\u5730\u5c06\u5b83\u4eec\u4e0e\u4e3b\u5145\u653e\u7535\u6d4b\u8bd5\u901a\u9053\u8fdb\u884c\u4efb\u610f\u914d\u7f6e\u3002<br \/>\n\u6570\u5b57I\/O\u901a\u5e38\u7528\u4e8e\u4e0e\u5916\u90e8\u786c\u4ef6\u4fe1\u53f7\u6216\u5f00\u5173\u7684\u4e92\u52a8\u64cd\u4f5c\uff0c\u5982\u62a5\u8b66\u4fe1\u53f7\u91c7\u96c6\u3001\u5f00\u5173\u98ce\u6247\u3001\u9600\u95e8\u7b49\u4fe1\u53f7\u7684\u8f93\u51fa\u7b49\u3002\n<strong>\u6a21\u62df\u8f93\u5165\/\u8f93\u51fa\uff08Analog I\/O\uff09<\/strong> \u8fd9\u4e9b\u901a\u9053\u5141\u8bb8 Arbin \u7cfb\u7edf\u53d1\u9001\u548c\u63a5\u6536 (-10)-10V \u7535\u538b\u4fe1\u53f7\u6216\u4e0e\u5916\u90e8\u786c\u4ef6\u8fde\u63a5\u3002  \u8fd9\u4e9b\u901a\u9053\u529f\u80fd\u72ec\u7acb\uff0c\u56e0\u6b64\u7528\u6237\u53ef\u4ee5\u7075\u6d3b\u5730\u5c06\u5b83\u4eec\u4e0e\u4e3b\u5145\u653e\u7535\u6d4b\u8bd5\u901a\u9053\u8fdb\u884c\u4efb\u610f\u914d\u7f6e\u3002<br \/>\nAnalog I\/O are commonly used to interact with client facility hardware or external hardware used with flow battery applications.\n\t\t\t\t\t\tTemperature Control\n\t\t\t\t\t\t\t\t\t\t\tArbin <strong>MZTC\u591a\u6e29\u533a\u6e29\u7bb1<\/strong> \u5141\u8bb8\u7814\u7a76\u4eba\u5458\u5728\u591a\u4e2a\u5b8c\u5168\u72ec\u7acb\u7684\u5c0f\u578b\u6e29\u5ea6\u73af\u5883\u4ed3\u5185\u8fdb\u884c\u7535\u6c60\u6d4b\u8bd5\uff0c\u4e3a\u5b9e\u9a8c\u63d0\u4f9b\u7684\u6781\u5927\u7684\u7075\u6d3b\u6027\u3002<br \/>\n&#8211; Temperature range is [Ambient-10] to 60 degC.<br \/>\n&#8211; Interface trays are available for all cell types.<br \/>\n&#8211; Optionally add temperature sensors to mount on each cell.\n<p>Arbin&#8217;s <strong>\u7b2c\u4e09\u65b9\u6e29\u7bb1\u63a5\u53e3\u6a21\u5757\uff08MTCI\uff09<\/strong> \u5b83\u5141\u8bb8 Arbin \u8bd5\u9a8c\u7bb1\u5728\u8bd5\u9a8c\u8fc7\u7a0b\u4e2d\u81ea\u52a8\u8bbe\u7f6e\u8bd5\u9a8c\u7bb1\u6e29\u5ea6\u548c\u8bb0\u5f55\u8bd5\u9a8c\u7bb1\u8bfb\u6570\uff0c\u5e76\u540c\u6b65\u6240\u6709\u6570\u636e\u3002  \u8fd9\u4e0e\u8bb8\u591a\u54c1\u724c\u7684\u8bd5\u9a8c\u7bb1\u517c\u5bb9\uff0c\u4f46\u8be6\u60c5\u8bf7\u54a8\u8be2 Arbin \u9500\u552e\u5de5\u7a0b\u5e08\u3002<\/p>\n\t\t\t\t\t\tTemperature Measurement\n\t\t\t\t\t\t\t\t\t\t\tArbin offers <strong>\u70ed\u7535\u5076<\/strong> \u548c <strong>\u70ed\u654f\u7535\u963b<\/strong> \u8fd9\u4e9b\u4f20\u611f\u5668\u7c7b\u578b\u53ef\u5728\u6d4b\u8bd5\u8fc7\u7a0b\u4e2d\u6d4b\u91cf\u548c\u8bb0\u5f55\u6e29\u5ea6\u3002  \u5b83\u4eec\u7684\u529f\u80fd\u662f\u72ec\u7acb\u7684\uff0c\u56e0\u6b64\u7528\u6237\u53ef\u4ee5\u7075\u6d3b\u5730\u5c06\u5b83\u4eec\u4e0e\u4e3b\u5145\u653e\u7535\u6d4b\u8bd5\u901a\u9053\u8fdb\u884c\u4efb\u610f\u914d\u7f6e\u3002  \u6240\u6709\u6570\u636e\u90fd\u4e0e\u7535\u6c60\u5145\u653e\u7535\u6d4b\u8bd5\u6570\u636e\u81ea\u52a8\u540c\u6b65\u3002  \u53ef\u7528\u7684\u4f20\u611f\u5668\u7c7b\u578b\u5305\u62ec<br \/>\n&#8211; K-Type Thermocouples<br \/>\n&#8211; T-Type Thermocouples<br \/>\n&#8211; PT100 Thermistor (NOTE: <em>PT100\u70ed\u654f\u7535\u963b\u8f93\u5165\u4e0eArbin MZTC\u591a\u6e29\u533a\u6e29\u7bb1\u517c\u5bb9<\/em>.)<br \/>\n&#8211; 10kOhm Thermistor\n\t\t\t\t\t\tAuxiliary Voltage Measurement\n\t\t\t\t\t\t\t\t\t\t\t<p><strong>\u8f85\u52a9\u7535\u538b\u8f93\u5165\uff08auxV\uff09 <\/strong>\u53ef\u6dfb\u52a0\u5230\u4efb\u4f55 Arbin \u7cfb\u7edf\u4e2d\uff0c\u7528\u4e8e\u6d4b\u91cf\u591a\u7535\u6781\u7535\u6c60\u6216\u5b9e\u9a8c\u4e2d\u989d\u5916\u53c2\u6bd4\u7535\u6781\u7684\u7535\u538b\u3002  Arbin \u7cfb\u7edf\u53ef\u6dfb\u52a0\u4efb\u610f\u6570\u91cf\u7684\u8f85\u52a9\u7535\u538b\u8f93\u5165\u3002  \u5b83\u4eec\u7684\u529f\u80fd\u662f\u72ec\u7acb\u7684\uff0c\u56e0\u6b64\u7528\u6237\u53ef\u4ee5\u7075\u6d3b\u5730\u5c06\u5b83\u4eec\u4e0e\u4e3b\u5145\u653e\u7535\u6d4b\u8bd5\u901a\u9053\u8fdb\u884c\u4efb\u610f\u914d\u7f6e\u3002  \u6240\u6709\u6570\u636e\u5747\u4e0e Arbin \u4e3b\u6d4b\u8bd5\u6570\u636e\u540c\u6b65\u3002<\/p>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-0\" data-index=\"0\" aria-selected=\"true\" aria-controls=\"fl-tabs--panel-0\" aria-expanded=\"true\" role=\"tab\" tabindex=\"0\">\t\t\t\t\u81ea\u52a8\u6821\u51c6 Auto Calibration\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-1\" data-index=\"1\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-1\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\t\u7535\u6c60\u5939\u5177\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-2\" data-index=\"2\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-2\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\t\u6258\u76d8\u4e0e\u6d4b\u8bd5\u652f\u67b6\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-3\" data-index=\"3\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-3\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\t\u4e0d\u95f4\u65ad\u7535\u6e90\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-4\" data-index=\"4\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-4\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\tCANBus\/SMBus\t\t\t\t<\/a>\n\t\t\t\t\t\tAuto-Calibration\n\t\t\t\t\t\t\t\t\t\t\tArbin offers an optional <strong>\u81ea\u52a8\u6821\u51c6\u6a21\u5757<\/strong> which can be used to re-calibrate the system when needed.\u00a0 All Arbin test equipment include a calibration interface as standard that can use an external meter to check or perform re-calibration.\u00a0 The AutoCal module is used to automate this process and will function without the need for an external meter.<br \/>\n\u6ce8\u610f\uff1aArbin\u5efa\u8bae\u6bcf\u5e74\u68c0\u67e5\u4e00\u6b21\u8bbe\u5907\u7cbe\u5ea6\uff0c\u5e76\u6839\u636e\u9700\u8981\u8fdb\u884c\u91cd\u65b0\u6821\u51c6\u3002\n<p>\u81ea\u52a8\u6821\u51c6\u6a21\u5757\u7684\u6807\u51c6\u989d\u5b9a\u7535\u6d41\u53ef\u8fbe200A\uff0c\u800c\u6269\u5c55\u7684\u00a0<strong>\u9ad8\u7cbe\u5ea6\u5206\u6d41\u5668<\/strong> \u4e5f\u53ef\u7528\u4e8e600A\u7535\u6d41\u7684\u6821\u51c6\u3002<\/p>\n\t\t\t\t\t\t\u7535\u6c60\u5939\u5177\n\t\t\t\t\t\t\t\t\t\t\t<p>\u5404\u79cd\u7c7b\u578b\u7684 <strong>\u7535\u6c60\u5939\u5177<\/strong> \u53ef\u4e0e\u4efb\u4f55\u6d4b\u8bd5\u5b9e\u9a8c\u5ba4\u914d\u5957\u4f7f\u7528\u3002  Arbin \u63d0\u4f9b\u5355\u4e2a\u7ec6\u80de\u67b6\u4ee5\u53ca\u53ef\u4f7f\u7528\u8f83\u591a\u7ec6\u80de\u7684\u6258\u76d8\u548c\u6258\u67b6\u3002<\/p>\n<p>Individual cell holders are available for coincells, cylindrical cells, pouch cells, and a general interface with alligator clips.<\/p>\n<p>Multi-cell Trays are available for coincells, cylindrical cells, pouch cells, and a blank tray interface.\u00a0 A variety of rack sizes are available to house these cell trays.<\/p>\n\t\t\t\t\t\t\u6258\u76d8\u4e0e\u6d4b\u8bd5\u652f\u67b6\n\t\t\t\t\t\t\t\t\t\t\t<p>Arbin battery test equipment is always provided as a turnkey system with fully integrated chassis.\u00a0 They will be benchtop models or larger, floor-standing units.<\/p>\n<p><strong>\u8f85\u52a9\u673a\u67b6<\/strong> \u53ef\u5bb9\u7eb3\u591a\u4e2a Arbin \u6d4b\u8bd5\u8bbe\u5907\u6a21\u5757\u548c\/\u6216\u8f85\u52a9\u9009\u4ef6\uff0c\u5305\u62ec MZTC \u591a\u673a\u7bb1\u3002  \u5c3a\u5bf8\u5305\u62ec 15U\u300124U \u548c 36U\u3002  \u8fd9\u4e9b\u90fd\u662f\u843d\u5730\u5f0f\u673a\u67b6\uff0c\u53ef\u5e2e\u52a9\u7ec4\u7ec7\u5404\u79cd\u914d\u7f6e\u7684 Arbin \u786c\u4ef6\uff0c\u4ee5\u6ee1\u8db3\u4e0d\u65ad\u589e\u957f\u7684\u6d4b\u8bd5\u5b9e\u9a8c\u5ba4\u7684\u9700\u8981\u3002<\/p>\n<strong>\u7535\u6c60\u6d4b\u8bd5\u652f\u67b6<\/strong> \u4e5f\u53ef\u7528\u4e8e\u653e\u7f6e\u591a\u8282\u7535\u6c60\u6258\u76d8\u3002  \u5c3a\u5bf8\u5305\u62ec 5 \u5c42\u30018 \u5c42\u300116 \u5c42\u548c 24 \u5c42\u3002  \u8fd9\u4e9b\u90fd\u662f\u843d\u5730\u5f0f\u652f\u67b6\uff0c\u53ef\u5e2e\u52a9\u7ec4\u7ec7\u5927\u91cf\u5f85\u6d4b\u7535\u6c60\u3002  \u7535\u6c60\u6258\u76d8\u9700\u5355\u72ec\u8d2d\u4e70\u3002<br \/>\n(1 layer holds 1 tray.)\n\t\t\t\t\t\tUPS\n\t\t\t\t\t\t\t\t\t\t\t<p>Arbin\u63d0\u4f9b\u4e86\u4e00\u4e2a\u53ef\u9009\u7684 <strong>\u4e0d\u95f4\u65ad\u7535\u6e90<\/strong> (uninterruptable power supply) that is intended to provide power for the PC used with the Arbin battery test equipment.\u00a0 This allows the PC and Arbin software to continue running during a brief power outage and tests can automatically resume when power is restored.\u00a0 Relatively longer power outages will safely shut down the PC.\u00a0 Tests can always be resumed manually after any stoppage.<\/p>\n\t\t\t\t\t\tCANBus\/SMBus\n\t\t\t\t\t\t\t\t\t\t\t<p>Arbin\u63d0\u4f9b <strong>CANBus\/SMBus\u63a5\u53e3\uff0c\u00a0<\/strong>\u5141\u8bb8\u4f7f\u7528 CAN \u534f\u8bae\u5bf9 Arbin \u6d4b\u8bd5\u4eea\u8fdb\u884c\u5b9e\u65f6\u5916\u90e8\u63a7\u5236\u3002  \u8be5\u9009\u9879\u901a\u5e38\u7528\u4e8e\u7535\u6c60\u6a21\u5757\u548c\u7535\u6c60\u7ec4\uff0c\u4ee5\u4fbf\u4e0e BMS\uff08\u7535\u6c60\u7ba1\u7406\u7cfb\u7edf\uff09\u901a\u4fe1\uff0c\u4f46\u4e5f\u53ef\u7528\u4e8e\u7535\u6c60\u6d4b\u8bd5\uff0c\u4ee5\u6ee1\u8db3\u5ba2\u6237\u901a\u8fc7 CAN \u8fdb\u884c\u5916\u90e8\u63a7\u5236\u7684\u9700\u8981\u3002<\/p>\n<p>NOTE: Additional methods of external control are available through Arbin&#8217;s optional TCP\/IP interface (Arbin &#8220;CTI&#8221;).<\/p>\n<h2>\n\t\t\u9a6c\u4e0a\u83b7\u53d6\u62a5\u4ef7\n\t<\/h2>\n\t<p>\u8bf7\u586b\u5199\u6211\u4eec\u7684\u8054\u7cfb\u8868\u4ee5\u7d22\u53d6\u62a5\u4ef7\u5e76\u8fdb\u4e00\u6b65\u4e86\u89e3Arbin\u4eea\u5668\u3001\u7cbe\u51c6\u5339\u914d\u60a8\u7684\u6d4b\u8bd5\u9700\u6c42<\/p>\n\t\t\t<a href=\"https:\/\/www.arbin.com\/zh\/%e8%af%a2%e4%bb%b7\/\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t\t\t\t\u63d0\u4f9b\u9700\u6c42\u4fe1\u606f\uff0c\u5e76\u83b7\u53d6\u62a5\u4ef7\n\t\t\t\t\t<\/a>","protected":false},"excerpt":{"rendered":"<p>Download Brochure Regenerative Battery Test Series for Cells (RBT-Cell) Channel Voltage 6V, 10V, and 20V Models Channel Current \u00b1100A or \u00b1400A per channel, Up to 1,600A Channel Quantity Up to 64 Arbin&#8217;s RBT-Cell Battery Test Series is designed to meet the growing demand for regenerative battery testing. It offers high-current, cell-level test channels that use [&hellip;]<\/p>","protected":false},"author":14,"featured_media":21579,"parent":6360,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"","_seopress_titles_title":"RBT Cell Series | Arbin Instruments","_seopress_titles_desc":"The RBT Cell Series provides high-current, cell-level test channels that use Arbin's regenerative technology for reliable, efficient, testing and validation.","_seopress_robots_index":"","inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-21576","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/pages\/21576","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/comments?post=21576"}],"version-history":[{"count":0,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/pages\/21576\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/pages\/6360"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/media\/21579"}],"wp:attachment":[{"href":"https:\/\/www.arbin.com\/zh\/wp-json\/wp\/v2\/media?parent=21576"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}