{"id":54212,"date":"2025-10-08T09:33:58","date_gmt":"2025-10-08T14:33:58","guid":{"rendered":"https:\/\/www.arbin.com\/?p=54212"},"modified":"2025-11-27T04:49:57","modified_gmt":"2025-11-27T10:49:57","slug":"overview-about-what-arbin-products-to-choose-1","status":"publish","type":"post","link":"https:\/\/www.arbin.com\/ko\/overview-about-what-arbin-products-to-choose-1.html","title":{"rendered":"Overview about what Arbin products to choose &#8211; Voltage and Current Range"},"content":{"rendered":"<h4 data-renderer-start-pos=\"1\"><strong data-renderer-mark=\"true\">Arbin&#8217;s Battery Testing Systems<\/strong><\/h4>\r\n<p>Arbin&#8217;s main products are advanced <strong data-renderer-mark=\"true\">\ubc30\ud130\ub9ac \ud14c\uc2a4\ud2b8 \uc2dc\uc2a4\ud15c<\/strong> that accurately simulate real-world charge and discharge cycles. These systems help researchers, engineers, and manufacturers evaluate battery performance, safety, and lifespan under a wide range of conditions.<\/p>\r\n<h4 data-renderer-start-pos=\"304\"><strong data-renderer-mark=\"true\">Key Specifications<\/strong><\/h4>\r\n<p>Two of the most important specifications of a testing system are its <strong data-renderer-mark=\"true\">maximum channel voltage<\/strong> \uadf8\ub9ac\uace0 <strong data-renderer-mark=\"true\">maximum channel current<\/strong>. Together, these determine the limits at which the system can safely charge and discharge a battery &#8211; making them essential factors when selecting the right solution for your application.<\/p>\r\n<h4 data-renderer-start-pos=\"633\"><strong data-renderer-mark=\"true\">What This Article Covers<\/strong><\/h4>\r\n<p>This article provides an overview of the <strong data-renderer-mark=\"true\">voltage ranges<\/strong> \uadf8\ub9ac\uace0 <strong data-renderer-mark=\"true\">current ranges<\/strong> available across Arbin&#8217;s main product lines. In a follow-up article, we will explore Arbin&#8217;s <strong data-renderer-mark=\"true\">auxiliary products<\/strong>, which further expand testing capabilities.<\/p>\r\n<p><img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2025\/10\/arbin-product-overview-chart.png\" alt=\"arbin product overview chart\" width=\"2825\" height=\"1524\" \/><\/p>\r\n<p>Arbin Product Overview Graph above illustrates the <strong data-renderer-mark=\"true\">\ud604\uc7ac<\/strong> \uadf8\ub9ac\uace0 <strong data-renderer-mark=\"true\">voltage ranges<\/strong> of Arbin&#8217;s main products. However, a bit of elaboration will help clarify the details:<\/p>\r\n<h4 data-renderer-start-pos=\"1080\"><strong data-renderer-mark=\"true\">LBTS Series<\/strong><\/h4>\r\n<p><strong data-renderer-mark=\"true\">LBTS<\/strong> stands for <strong data-renderer-mark=\"true\">\uc2e4\ud5d8\uc2e4 \ubc30\ud130\ub9ac \ud14c\uc2a4\ud130<\/strong>, and is actually the next generation of the original <strong data-renderer-mark=\"true\">LBT<\/strong> series.<br \/>This product line is divided into two categories: <strong data-renderer-mark=\"true\">LBTS-Cell<\/strong> \uadf8\ub9ac\uace0 <strong data-renderer-mark=\"true\">LBTS \ubaa8\ub4c8<\/strong>.<\/p>\r\n<h3 id=\"LBTS-Cell\" data-renderer-start-pos=\"1287\"><strong data-renderer-mark=\"true\">LBTS-Cell<\/strong><\/h3>\r\n<ul data-indent-level=\"1\">\r\n<li><strong data-renderer-mark=\"true\">Max Voltage Range:<\/strong> 5V &#8211; 10V<\/li>\r\n<li><strong data-renderer-mark=\"true\">5V Range:<\/strong><\/li>\r\n<\/ul>\r\n<p>&#8211; Max Current: <strong data-renderer-mark=\"true\">20A per channel<\/strong><\/p>\r\n<p>&#8211; For high-channel-count systems, the <strong data-renderer-mark=\"true\">recommended current<\/strong> is 10A per channel.<\/p>\r\n<ul>\r\n<li data-renderer-start-pos=\"1460\"><strong data-renderer-mark=\"true\">10V Range:<\/strong><\/li>\r\n<\/ul>\r\n<p>&#8211; Max Current: <strong data-renderer-mark=\"true\">300A per channel<\/strong><\/p>\r\n<h3 id=\"LBTS-Module\" data-renderer-start-pos=\"1513\"><strong data-renderer-mark=\"true\">LBTS \ubaa8\ub4c8<\/strong><\/h3>\r\n<ul data-indent-level=\"1\">\r\n<li><strong data-renderer-mark=\"true\">Max Voltage Range:<\/strong> 20V &#8211; 150V<\/li>\r\n<li><strong data-renderer-mark=\"true\">Max Current Range:<\/strong> 80A<\/li>\r\n<\/ul>\r\n<h4 id=\"RBT4-Series\" data-renderer-start-pos=\"1591\"><strong data-renderer-mark=\"true\">RBT4 Series<\/strong><\/h4>\r\n<h3 id=\"RBT4-Cell\" data-renderer-start-pos=\"1604\"><strong data-renderer-mark=\"true\">RBT4-Cell<\/strong><\/h3>\r\n<ul data-indent-level=\"1\">\r\n<li><strong data-renderer-mark=\"true\">Max Current Range:<\/strong> 100A &#8211; 400A per channel (parallel up to 1600A)<\/li>\r\n<li><strong data-renderer-mark=\"true\">Max Voltage:<\/strong> 20V<\/li>\r\n<\/ul>\r\n<h3 id=\"RBT4-Module\" data-renderer-start-pos=\"1717\"><strong data-renderer-mark=\"true\">RBT4-Module<\/strong><\/h3>\r\n<ul data-indent-level=\"1\">\r\n<li><strong data-renderer-mark=\"true\">Current Range:<\/strong> 75A &#8211; 300A per channel (parallel up to 1200A)<\/li>\r\n<li><strong data-renderer-mark=\"true\">Max Voltage Range:<\/strong> 30V &#8211; 200V<\/li>\r\n<\/ul>\r\n<h3 data-renderer-start-pos=\"1796\"><strong data-renderer-mark=\"true\">RBT3<\/strong> offers the highest current and voltage ranges of all Arbin products.<\/h3>\r\n<ul data-indent-level=\"1\">\r\n<li><strong data-renderer-mark=\"true\">Max Current Range:<\/strong> 150A &#8211; 400A per channel (parallel to achieve thousands of amps)<\/li>\r\n<li><strong data-renderer-mark=\"true\">Max Voltage Range:<\/strong> 300V &#8211; 1000V<\/li>\r\n<\/ul>\r\n<p>You can see that RBT4 maximum voltage is only up to 200V. Therefore, when you want to test something higher than 200V but still less than 300V, we will need to introduce RBT3 300V, this will also cover the voltage range that is bigger than 200V but still smaller than 300V<\/p>\r\n<h3 data-renderer-start-pos=\"2304\"><strong data-renderer-mark=\"true\">Parallel Capability:<\/strong><\/h3>\r\n<p>One of Arbin&#8217;s advantages is the ability to parallel channels to achieve higher current.<br \/>For example, you can combine four 400A channels to achieve 1600A. <strong data-renderer-mark=\"true\">Higher voltage may also be achieved by hardware serializing multiple<\/strong> <strong>\ucc44\ub110<\/strong> (RBT series only).<\/p>\r\n<p>See more:\u00a0\u00a0 <strong><a href=\"https:\/\/www.arbin.com\/ko\/overview-about-what-arbin-product-to-choose-regenerative-features.html\/\">Overview about what Arbin product to choose &#8211; Regenerative features<\/a><\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>Arbin&#8217;s Battery Testing Systems Arbin&#8217;s main products are advanced battery testing systems that accurately simulate real-world charge and discharge cycles. These systems help researchers, engineers, and manufacturers evaluate battery performance, safety, and lifespan under a wide range of conditions. Key Specifications Two of the most important specifications of a testing system are its maximum channel [&hellip;]<\/p>","protected":false},"author":6,"featured_media":54216,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[104],"tags":[],"class_list":["post-54212","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-arbin-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/posts\/54212","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/comments?post=54212"}],"version-history":[{"count":12,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/posts\/54212\/revisions"}],"predecessor-version":[{"id":62180,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/posts\/54212\/revisions\/62180"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/media\/54216"}],"wp:attachment":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/media?parent=54212"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/categories?post=54212"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/tags?post=54212"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}