{"id":22717,"date":"2024-08-29T13:51:32","date_gmt":"2024-08-29T18:51:32","guid":{"rendered":"https:\/\/dev.arbin.com\/?page_id=22717"},"modified":"2026-11-13T08:28:03","modified_gmt":"2026-11-13T14:28:03","slug":"auxiliary","status":"publish","type":"page","link":"https:\/\/www.arbin.com\/ko\/battery-research\/auxiliary.html","title":{"rendered":"\ubcf4\uc870(AUX)"},"content":{"rendered":"<a href=\"https:\/\/www.arbin.com\/ko\/\">\ud648<\/a> &nbsp;&rsaquo;&nbsp; Auxiliary Modules\n    <header>\n      <img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2025\/04\/MZTC-3D_Aux-2.png\" alt=\"Arbin auxiliary modules for battery testers\"\/>\n        <p>Auxiliary inputs and outputs for battery testing<\/p>\n        <h1>Auxiliary Modules: Add Measurement, Safety and Control to Any Arbin Tester<\/h1>\n        <p>Auxiliary modules give an Arbin battery tester extra inputs and outputs: <strong>temperature, voltage and pressure<\/strong> readings, <strong>CAN Bus and SMBus<\/strong> communication, <strong>chamber control<\/strong>\ubc0f <strong>analog and digital I\/O<\/strong>. Order them with a new system or add them to a tester you already own.<\/p>\n        <a href=\"https:\/\/www.arbin.com\/ko\/request-a-quote.html\/\">Request the Auxiliary Catalog<\/a><a href=\"#measure\">See the Modules<\/a>\n    <\/header>\n      <a href=\"#how\">How It Works<\/a><a href=\"#measure\">Measure<\/a><a href=\"#control\">Communicate and Control<\/a><a href=\"#uses\">What You Can Do<\/a><a href=\"#specs\">\uc0ac\uc591<\/a><a href=\"#later\">Add Later<\/a>\n    <section id=\"how\">\n      <h2>How auxiliaries work<\/h2><p>The tester charges and discharges the battery. Auxiliary modules bring every other signal in the test into the same schedule and the same data file.<\/p>\n        <figure><img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/2026-11-13-auxiliary-tester-connection.png\" alt=\"Arbin battery tester connected to an auxiliary chassis and control computer over Ethernet\"\/><figcaption>The auxiliary chassis sits beside the tester and connects over Ethernet (TCP\/IP).<\/figcaption><\/figure>\n          1<h3>Choose the inputs and outputs<\/h3><p>Pick the modules the test needs: temperature, voltage, pressure, CAN Bus, SMBus, chamber control, analog or digital I\/O. Module types can be mixed.<\/p>\n          2<h3>Connect to the tester<\/h3><p>The modules are housed in an auxiliary chassis that connects over Ethernet. It is air-cooled, runs from a 100 to 240&nbsp;VAC outlet and needs no cooling infrastructure.<\/p>\n          3<h3>Use the signals in the test schedule<\/h3><p>In MITS, each auxiliary channel is mapped to a test channel. Its value is logged with current and voltage, and can end a step, trigger a safety limit or drive an external device.<\/p>\n    <\/section>\n    <section id=\"measure\">\n      <h2>Measure more than current and voltage<\/h2><p>Extra measurement channels, recorded alongside the tester data.<\/p>\n      <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-temperature.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>Temperature inputs<\/h3><p>Thermocouple, PT100 and thermistor inputs for cell surface, tab and chamber temperatures. Each reading can be logged, used to end a test step, or set as a safety limit.<ul><li>Sensor typesT and K thermocouple, PT100, 10&nbsp;k&Omega; thermistor<\/li><li>Module accuracy&plusmn;0.1&nbsp;&deg;C PT100, &plusmn;1&nbsp;&deg;C thermocouple<\/li><li>Widest range&minus;200 to 1,200&nbsp;&deg;C (K-type)<\/li><\/ul><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-voltage.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>Voltage inputs<\/h3>Extra voltage sense channels for reference electrodes in three-electrode cells, or for individual cell and module voltages inside a pack.<ul><li>Ranges&plusmn;5, &plusmn;10, &plusmn;25, &plusmn;50, &plusmn;100&nbsp;V<\/li><li>Accuracy&plusmn;0.05% FSR<\/li><li>Resolution24-bit<\/li><li>Common modeUp to 500&nbsp;V<\/li><\/ul><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-gauge.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>Pressure inputs<\/h3>Inputs for millivolt-output pressure transducers. Used for pouch cell swelling and for internal pressure in cylindrical and prismatic cells.<\/p><ul><li>Sensor signal0 to 10&nbsp;mV or 0 to 100&nbsp;mV<\/li><li>Accuracy&plusmn;0.1% FSR<\/li><li>Sensor supply15&nbsp;V, built in<\/li><\/ul>\n    <\/section>\n    <section id=\"control\">\n      <h2>Communicate with and control other equipment<\/h2><p>Connect the tester to the BMS, the temperature chamber and the rest of the test setup.<\/p>\n      <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-can-bus.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>CAN \ubc84\uc2a4<\/h3><p>Reads messages from a battery management system and sends messages to it. BMS values such as state of charge, temperature and fault flags can be logged and used to control or stop the test.<ul><li>ProtocolsCAN 2.0 and CAN FD<\/li><li>Identifiers11-bit or 29-bit<\/li><li>Baud rate125k to 1M<\/li><li>SetupDBC file import<\/li><\/ul><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-smbus.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>SMBus<\/h3>Reads and writes the registers of a smart battery during a test. Register values are logged with the tester data and can control or limit the test.<ul><li>ProtocolsSMBus 1.1 and 2.0<\/li><li>Clock speed10 to 100&nbsp;kHz<\/li><li>FitOne SMBus input per test channel<\/li><\/ul><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-chamber.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>Chamber interface (MTCI)<\/h3>Lets the test schedule set the temperature of a third-party chamber and wait for it before the next step. Chamber readings are logged with the cell data.<ul><li>ConnectionRS-232<\/li><li>ControlsTemperature, and humidity where the chamber supports it<\/li><li>FitOne interface per chamber<\/li><\/ul><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-analog.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>Analog I\/O<\/h3>Analog signals for flow controllers, pumps, regulators and valves, with open-loop or closed-loop (PID) control from the test schedule.<ul><li>Output&minus;10 to 10&nbsp;V<\/li><li>Option4 to 20&nbsp;mA current mode<\/li><li>Accuracy&plusmn;0.1% FSR<\/li><\/ul><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-digital.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>\ub514\uc9c0\ud138 I\/O<\/h3>Switched inputs and outputs that connect the tester to interlocks, emergency stops, alarms, fans and PLCs.<ul><li>TypesRelay or TTL (0 to 5&nbsp;V)<\/li><li>Relay outputUp to 30&nbsp;V, 1&nbsp;A<\/li><\/ul><h3>Tell us the signals in your test<\/h3>Send the tester model and what you need to measure or control. We will recommend the modules and send the auxiliary catalog.<a href=\"https:\/\/www.arbin.com\/ko\/request-a-quote.html\/\">Request the Catalog<\/a><\/p>\n    <\/section>\n    <section id=\"uses\">\n      <h2>What you can do with auxiliaries<\/h2>\n      <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-gauge.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>\uce21\uc815 \ubc29\ubc95<\/h3><p>Record the signals that explain the test result.<\/p><ul><li>&#10003;Reference electrode voltage in three-electrode cells<\/li><li>&#10003;Cell and module voltages inside a pack<\/li><li>&#10003;Cell surface and chamber temperature<\/li><li>&#10003;Pouch cell swelling and internal cell pressure<\/li><li>&#10003;BMS readings compared with direct measurements<\/li><\/ul>\n      <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-safety.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>\uc548\uc804<\/h3><p>Let the test react before a problem grows.<\/p><ul><li>&#10003;Temperature limits that stop a channel<\/li><li>&#10003;Pressure limits that stop a channel<\/li><li>&#10003;Door interlocks and emergency stops through digital inputs<\/li><li>&#10003;Alarms and fans switched by relay outputs<\/li><li>&#10003;BMS fault flags read over CAN Bus<\/li><\/ul>\n      <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/11\/arbin-aux-icon-control.png\" alt=\"\" width=\"30\" height=\"30\"\/><h3>Control<\/h3><p>Run the whole setup from one test schedule.<\/p><ul><li>&#10003;Chamber temperature set step by step<\/li><li>&#10003;Test steps that wait for the chamber to reach temperature<\/li><li>&#10003;Messages sent to the BMS over CAN Bus<\/li><li>&#10003;Pumps, valves and flow controllers, for example on flow batteries<\/li><li>&#10003;Signals exchanged with PLCs and automation<\/li><\/ul>\n    <\/section>\n    <section id=\"specs\">\n      <h2>Specifications at a glance<\/h2><p>Headline figures for each module type. The auxiliary catalog has the full specifications.<\/p>\n      <table><thead><tr><th>\ubaa8\ub4c8<\/th><th>Signal<\/th><th>\ubc94\uc704<\/th><th>Accuracy or detail<\/th><\/tr><\/thead><tbody>\n      <tr><td>Temperature, thermocouple<\/td><td>Type T or Type K<\/td><td>&minus;270 to 400&nbsp;&deg;C (T), &minus;200 to 1,200&nbsp;&deg;C (K)<\/td><td>&plusmn;1&nbsp;&deg;C<\/td><\/tr>\n      <tr><td>Temperature, PT100<\/td><td>PT100 RTD<\/td><td>&minus;50 to 200&nbsp;&deg;C<\/td><td>&plusmn;0.1&nbsp;&deg;C<\/td><\/tr>\n      <tr><td>Temperature, thermistor<\/td><td>10&nbsp;k&Omega; thermistor<\/td><td>&minus;80 to 150&nbsp;&deg;C<\/td><td>&plusmn;0.2&nbsp;&deg;C<\/td><\/tr>\n      <tr><td>\uc804\uc555<\/td><td>Isolated voltage input<\/td><td>&plusmn;5, &plusmn;10, &plusmn;25, &plusmn;50 or &plusmn;100&nbsp;V<\/td><td>&plusmn;0.05% FSR, 24-bit, common mode up to 500&nbsp;V<\/td><\/tr>\n      <tr><td>Pressure<\/td><td>Millivolt-output transducer<\/td><td>0 to 10&nbsp;mV or 0 to 100&nbsp;mV<\/td><td>&plusmn;0.1% FSR, 15&nbsp;V sensor supply<\/td><\/tr>\n      <tr><td>CAN \ubc84\uc2a4<\/td><td>CAN 2.0 and CAN FD<\/td><td>125k, 250k, 500k or 1M baud<\/td><td>11-bit or 29-bit identifiers, DBC file import<\/td><\/tr>\n      <tr><td>SMBus<\/td><td>SMBus 1.1 and 2.0<\/td><td>10 to 100&nbsp;kHz clock<\/td><td>Read and write registers<\/td><\/tr>\n      <tr><td>Chamber interface (MTCI)<\/td><td>RS-232<\/td><td>One chamber per interface<\/td><td>Temperature, and humidity where the chamber supports it<\/td><\/tr>\n      <tr><td>Analog I\/O<\/td><td>Voltage, or current as an option<\/td><td>&minus;10 to 10&nbsp;V, or 4 to 20&nbsp;mA<\/td><td>&plusmn;0.1% FSR, &plusmn;40&nbsp;&micro;A in current mode<\/td><\/tr>\n      <tr><td>\ub514\uc9c0\ud138 I\/O<\/td><td>Relay or TTL<\/td><td>Relay output up to 30&nbsp;V, 1&nbsp;A<\/td><td>TTL at 0 to 5&nbsp;V logic<\/td><\/tr>\n      <\/tbody><\/table>\n      <p>Temperature ranges and accuracies are for the module. The sensor may have a narrower range and adds its own tolerance. Compatible chamber controllers for the chamber interface are listed on request. Specifications are subject to change.<\/p>\n    <\/section>\n    <section id=\"later\">\n        <h2>Add them now or later<\/h2><p>Auxiliaries do not have to be decided on day one. Start with the channels you need today and add inputs and outputs when the test plan changes.<\/p>\n        <ul>\n          <li>&#10003;Ordered with a new tester, auxiliaries arrive configured and ready to use.<\/li>\n          <li>&#10003;Added later, they connect to the tester you already have over Ethernet.<\/li>\n          <li>&#10003;Arbin support enables the new channels in MITS by remote session.<\/li>\n          <li>&#10003;Tell us the tester model and the signals you need, and we will match the right hardware.<\/li>\n        <\/ul>\n    <\/section>\n    <section id=\"related\">\n      <h2>More options for your tester<\/h2>\n      <a href=\"https:\/\/www.arbin.com\/ko\/solutions\/eis-integration.html\/\">EIS integrationImpedance spectroscopy on Arbin test channels.View page &rsaquo;<\/a>\n      <a href=\"https:\/\/www.arbin.com\/ko\/battery-research\/multi-zone-temperature-chamber.html\/\">Multi-Zone Temperature Chamber4 or 8 independent temperature zones for cells.View page &rsaquo;<\/a>\n      <a href=\"https:\/\/www.arbin.com\/ko\/battery-research\/battery-holders-and-battery-racks.html\/\">Battery holders and racksHolders for coin, cylindrical and pouch cells.View page &rsaquo;<\/a>\n      <a href=\"https:\/\/www.arbin.com\/ko\/battery-research\/multi-zone-open-rack.html\/\">Multi-Zone Open RackOpen rack with four compartments for battery trays.View page &rsaquo;<\/a>\n      Auto-calibrationOne calibration system for the tester and its auxiliaries.\n    <\/section>\n      <h2>Tell us what you need to measure or control<\/h2>\n      <p>Send us your tester model and the signals in your test. We will reply with the auxiliary catalog and a recommendation.<\/p>\n      <a href=\"https:\/\/www.arbin.com\/ko\/request-a-quote.html\/\">Request the Auxiliary Catalog<\/a><a href=\"https:\/\/www.arbin.com\/ko\/contact-us.html\/\">Talk to an Engineer<\/a>","protected":false},"excerpt":{"rendered":"<p>Home &nbsp;&rsaquo;&nbsp; Auxiliary Modules Auxiliary inputs and outputs for battery testing Auxiliary Modules: Add Measurement, Safety and Control to Any Arbin Tester Auxiliary modules give an Arbin battery tester extra inputs and outputs: temperature, voltage and pressure readings, CAN Bus and SMBus communication, chamber control, and analog and digital I\/O. Order them with a new [&hellip;]<\/p>\n","protected":false},"author":27,"featured_media":22720,"parent":22204,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-22717","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/pages\/22717","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/comments?post=22717"}],"version-history":[{"count":8,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/pages\/22717\/revisions"}],"predecessor-version":[{"id":203299,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/pages\/22717\/revisions\/203299"}],"up":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/pages\/22204"}],"wp:attachment":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/media?parent=22717"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}