{"id":1633,"date":"2022-05-27T14:18:59","date_gmt":"2022-05-27T19:18:59","guid":{"rendered":"https:\/\/arbin.com\/?page_id=1633"},"modified":"2024-05-14T14:46:33","modified_gmt":"2024-05-14T19:46:33","slug":"rbt-%ec%8b%9c%eb%a6%ac%ec%a6%88","status":"publish","type":"page","link":"https:\/\/www.arbin.com\/ko\/battery-test-equipment\/battery-test-product-series\/rbt-series.html","title":{"rendered":"RBT \uc2dc\ub9ac\uc988"},"content":{"rendered":"\n\n\t<nav  aria-label=\"breadcrumb\"><ol class=\"breadcrumb\" itemscope itemtype=\"https:\/\/schema.org\/BreadcrumbList\"><li class=\"breadcrumb-item active\" aria-current=\"page\" itemprop=\"itemListElement\" itemscope itemtype=\"https:\/\/schema.org\/ListItem\"><span itemprop=\"name\">Home<\/span><meta itemprop=\"position\" content=\"1\"><\/li><\/ol><\/nav>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/plugins\/bb-plugin\/img\/pixel.png\" alt=\"\" itemprop=\"image\" onerror=\"this.style.display='none'\"  \/>\n<h1>\n\t\tRegenerative Battery Test Series\n\t<\/h1>\n<h4>\n\t\tRBT Product Range\n\t<\/h4>\n\t<table>\n<tbody>\n<tr>\n<td><strong>Channel Voltage<\/strong><\/td>\n<td>60 &#8211; 1,500V<\/td>\n<\/tr>\n<tr>\n<td><strong>Channel Current<\/strong><\/td>\n<td>50 &#8211; 1,000A<\/td>\n<\/tr>\n<tr>\n<td><strong>Regenerative Efficiency\u00a0<\/strong><\/td>\n<td>&gt;90%<\/td>\n<\/tr>\n<tr>\n\n\n<\/tr>\n<tr>\n\n\n<\/tr>\n<\/tbody>\n<\/table>\n\t<p>Arbin&#8217;s Regenerative Battery Testing (<strong>RBT<\/strong>) series is specifically designed for testing high-power battery packs. Engineered with electric vehicles, military technology, and stationary grid storage in mind, these pack testing systems can simulate complex, real-world applications such as drive profiles, cranking amp applications, and other custom profiles. The regenerative circuitry within each RBT system allows power to be discharged back to the grid, making it a more economical battery test solution for pack voltage up to 1000V and maximum power up to 1MW.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/12\/Battery-Test-Lab-Rz-blue01-500x375.png\" alt=\"Arbin battery cell testing in a temperature chamber\" itemprop=\"image\" height=\"375\" width=\"500\" title=\"Battery Test Lab - Rz - blue01\" onerror=\"this.style.display='none'\"  \/>\n<h2>\n\t\tArbin&#8217;s RBT Series Standard Models\n\t<\/h2>\n\t\t\t<a href=\"\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t\t\t\tLow Voltage\n\t\t\t\t\t<\/a>\n\t<p><strong>Small module and pack testing up to 200V<\/strong><\/p>\n<ul>\n<li>Voltage from 60V up to 200V<\/li>\n<li>Current ranges from 100A up to 600A<\/li>\n<\/ul>\n\t\t\t\t\t<a href=\"javascript:void(0);\" id=\"fl-accordion--label-0\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-0\">RBT 60V<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-0\" tabindex=\"-1\" aria-controls=\"fl-accordion--panel-0\"><i>Collapse<\/i><\/a>\n\t\t\t\t\tVoltage Range: <strong>5V<\/strong><b> to 60V (0V Option)<\/b><br \/>\nChannel Max Current: <strong>100A up to 600A<\/strong><br \/>\nChannel Count:<strong> 2~18+<\/strong>\n\t\t\t\t\t<a href=\"javascript:void(0);\" id=\"fl-accordion--label-1\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-1\">RBT 100V<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-1\" tabindex=\"-1\" aria-controls=\"fl-accordion--panel-1\"><i>Expand<\/i><\/a>\n\t\t\t\t\tVoltage Range: <strong>5V<\/strong><b> to 100V (0V Option)<\/b><br \/>\nChannel Max Current: <strong>100A up to 600A<\/strong><br \/>\nChannel Count:<strong> 2~18+<\/strong>\n\t\t\t\t\t<a href=\"javascript:void(0);\" id=\"fl-accordion--label-2\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-2\">RBT 200V<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-2\" tabindex=\"-1\" aria-controls=\"fl-accordion--panel-2\"><i>Expand<\/i><\/a>\n\t\t\t\t\tVoltage Range: <strong>5V<\/strong><b> to 200V (0V Option)<\/b><br \/>\nChannel Max Current: <strong>100A up to 600A<\/strong><br \/>\nChannel Count:<strong> 2~18+<\/strong>\n\t\t\t<a href=\"\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t\t\t\tMedium Voltage\n\t\t\t\t\t<\/a>\n\t<p><strong>Mid-size modules and packs up to 600V<\/strong><\/p>\n<ul>\n<li>Voltage from 400V up to 600V<\/li>\n<li>Current ranges from 100A up to 500A<\/li>\n<\/ul>\n\t\t\t\t\t<a href=\"javascript:void(0);\" id=\"fl-accordion--label-0\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-0\">RBT 400V<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-0\" tabindex=\"-1\" aria-controls=\"fl-accordion--panel-0\"><i>Collapse<\/i><\/a>\n\t\t\t\t\tVoltage Range: <strong>15V<\/strong><b> to 400V<\/b><br \/>\nChannel Max Current: <strong>100A up to 500A<\/strong><br \/>\nChannel Count:<strong> 2~12+<\/strong>\n\t\t\t\t\t<a href=\"javascript:void(0);\" id=\"fl-accordion--label-1\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-1\">RBT 500V<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-1\" tabindex=\"-1\" aria-controls=\"fl-accordion--panel-1\"><i>Expand<\/i><\/a>\n\t\t\t\t\tVoltage Range: <strong>15V<\/strong><b> to 500V\u00a0<\/b><br \/>\nChannel Max Current: <strong>100A up to 400A<\/strong><br \/>\nChannel Count:<strong> 2~12+<\/strong>\n\t\t\t\t\t<a href=\"javascript:void(0);\" id=\"fl-accordion--label-2\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-2\">RBT 600V<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-2\" tabindex=\"-1\" aria-controls=\"fl-accordion--panel-2\"><i>Expand<\/i><\/a>\n\t\t\t\t\tVoltage Range: <strong>15V<\/strong><b> to 600V\u00a0<\/b><br \/>\nChannel Max Current: <strong>100A up to 300A<\/strong><br \/>\nChannel Count:<strong> 2~10+<\/strong>\n\t\t\t<a href=\"\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t\t\t\tHigh Voltage\n\t\t\t\t\t<\/a>\n\t<p><strong>High voltage pack testing up to 1,500V<\/strong><\/p>\n<ul>\n<li>Voltage from 700V up to 1,000V<\/li>\n<li>Current ranges from 100A up to 300A<\/li>\n<\/ul>\n\t\t\t\t\t<a href=\"javascript:void(0);\" id=\"fl-accordion--label-0\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-0\">RBT 700V<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-0\" tabindex=\"-1\" aria-controls=\"fl-accordion--panel-0\"><i>Collapse<\/i><\/a>\n\t\t\t\t\tVoltage Range: <strong>18V<\/strong><b> to 700V\u00a0<\/b><br \/>\nChannel Max Current: <strong>100A up to 300A<\/strong><br \/>\nChannel Count:<strong> 2~12<\/strong>\n\t\t\t\t\t<a href=\"javascript:void(0);\" id=\"fl-accordion--label-1\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-1\">RBT 800V<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-1\" tabindex=\"-1\" aria-controls=\"fl-accordion--panel-1\"><i>Expand<\/i><\/a>\n\t\t\t\t\tVoltage Range: 36<strong>V<\/strong><b> to 800V (0V Option)<\/b><br \/>\nChannel Max Current: <strong>100A up to 250A<\/strong><br \/>\nChannel Count:<strong> 2~12+<\/strong>\n\t\t\t\t\t<a href=\"javascript:void(0);\" id=\"fl-accordion--label-2\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-2\">RBT 900V<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-2\" tabindex=\"-1\" aria-controls=\"fl-accordion--panel-2\"><i>Expand<\/i><\/a>\n\t\t\t\t\tVoltage Range: 36<strong>V<\/strong><b> to 900V\u00a0<\/b><br \/>\nChannel Max Current: <strong>100A up to 200A<\/strong><br \/>\nChannel Count:<strong> 2~12<\/strong>\n\t\t\t\t\t<a href=\"javascript:void(0);\" id=\"fl-accordion--label-3\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-3\">RBT 1000V<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-3\" tabindex=\"-1\" aria-controls=\"fl-accordion--panel-3\"><i>Expand<\/i><\/a>\n\t\t\t\t\tVoltage Range: <strong>36V<\/strong><b> to 1000V\u00a0<\/b><br \/>\nChannel Max Current: <strong>100A up to 200A<\/strong><br \/>\nChannel Count:<strong> 2~12<\/strong>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2023\/01\/MODULE-PACK-BATTERY-TESTING_hardware-performance-of-rbt-system-1.png\" alt=\"Hardware performance of Arbin&#039;s RBT system\" itemprop=\"image\" height=\"317\" width=\"153\" title=\"MODULE-PACK-BATTERY-TESTING_hardware-performance-of-rbt-system\" onerror=\"this.style.display='none'\"  \/>\n<h2>\n\t\tReliable Performance with Arbin&#8217;s Regenerative Battery Testers\n\t<\/h2>\n\t\t<h3>\u00b10.05% FS Control &#038; Measurement Accuracy<br \/>16-Bit Control &#038; Measurement Resolution<\/h3><p>All Arbin regenerative test systems have 16-bit control and measurement resolution, and \u00b10.05% FSR accuracy to provide the highest quality results in the industry.<\/p>\n\t\t<h3>True Bipolar Power Supply<\/h3><p>Arbin&#8217;s true bipolar power supply has no switching time between charge\/discharge, so dynamic EV drive profiles are accurately performed. Leading competitors have 5ms+ switching time which causes drive profiles to lag over time.<\/p>\n\t\t<h3>Power Factor >0.99<br \/>Regenerative Circuitry with >90% Efficiency<br \/>100% Duty Cycle<\/h3><p>Highly efficient circuitry and power density minimize the cost of operation compared to similar systems. Each Arbin RBT system is engineered and over-built to handle <strong>100% duty cycle at maximum power<\/strong>.<\/p>\n\t\t<h3>Data Sampling at 0.3ms<br \/>Data Logging at 5ms or 2000 pts Per Second<\/h3><p>High performance integrated microcontrollers allow fast data sampling, and ability to log every detail of the charge\/discharge simulation.<\/p>\n\t<p>Each RBT system comes standard with <strong>multiple current ranges<\/strong>, and each current range can be tailored to fit your application.<\/p>\n<p><strong>Current rise time<\/strong> is also excellent, specified at 10ms or less (depending on your system&#8217;s current specification).<\/p>\n<p>All channels are fully independent, but can also be combined to <strong>operate in parallel for increased current-handling<\/strong> capacity.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2023\/01\/MODULE-PACK-BATTERY-TESTING_rbt-current-output-capability.png\" alt=\"RBT current output capability\" itemprop=\"image\" height=\"478\" width=\"492\" title=\"MODULE-PACK-BATTERY-TESTING_rbt-current-output-capability\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/06\/ELECTRIC-VEHICLE-BATTERY_TESTING_drive-profile-simulation-ev-battery-pack.png\" alt=\"ELECTRIC VEHICLE BATTERY TESTING Drive Profile Simulation EV Battery Pack\" itemprop=\"image\" height=\"401\" width=\"746\" title=\"ELECTRIC VEHICLE BATTERY TESTING Drive Profile Simulation EV Battery Pack\" onerror=\"this.style.display='none'\"  \/>\n<h2>\n\t\tRegenerative Battery Test Equipment for Advanced Simulations\n\t<\/h2>\n\t<p>Arbin&#8217;s RBT series of battery test equipment is capable of advanced, high-speed simulations. Users can upload pre-defined data or control the simulation dynamically via CAN communication.<\/p>\n<p><strong>Key Features:<\/strong><\/p>\n<ul>\n<li>Profile Types: Time vs. Current, Time vs. Power, Time vs. Load<\/li>\n<li>Up to 1 million data points<\/li>\n<li>True Bipolar Circuitry so no switching between charge and discharge<\/li>\n<li>Data Acquisition Range: Up to 5ms<\/li>\n<\/ul>\n<p>Compared to traditional battery cycling that may use exclusively constant current and constant voltage (CC-CV) charge\/discharge profiles, EV testing applications require charge\/discharge based on various real-world applications. These charge\/discharge profiles are highly dynamic and require much greater current demands relative to &#8220;traditional&#8221; testing.<\/p>\n<h2>\n\t\tCANBus Communication and Regenerative Battery Testing\n\t<\/h2>\n\t<p>Arbin&#8217;s RBT is the only tester that allows dynamic control of charge and discharge via the CAN protocol. This functionality allows users to control the Arbin tester with a Battery Management System (BMS).<\/p>\n<p>CANBus Features of the RBT Series:<\/p>\n<ul>\n<li>Allows BMS to fully control RBT charge\/discharge<\/li>\n<li>Easily import CAN database and customize<\/li>\n<li>Read\/write integration with battery management system<\/li>\n<li>Offers easy-to-navigate drop-down menu selections<\/li>\n<li>Create customized CAN reports to compare BMS data<\/li>\n<li>No 3rd-party equipment, DLL package, or license is needed<\/li>\n<li>Extended or Standard Frame Type<\/li>\n<\/ul>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2023\/01\/MODULE-PACK-BATTERY-TESTING_can-communication.png\" alt=\"RBT Can Communication Screenshots\" itemprop=\"image\" height=\"403\" width=\"493\" title=\"MODULE-PACK-BATTERY-TESTING_can-communication\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/08\/EV-charging-station-for-electric-car-in-concept-of-green-energy-and-eco-power-1339867675_2869x1049-1024x374.jpeg\" alt=\"EV charging station for electric car in concept of green energy and eco power\" itemprop=\"image\" height=\"374\" width=\"1024\" title=\"EV charging station for electric car in concept of green energy and eco power\" onerror=\"this.style.display='none'\"  \/>\n<h2>\n\t\tReliable and Safe Battery Pack Test Equipment\n\t<\/h2>\n\t<p>Battery pack testing requires both dependability and safety, two core design principles in Arbin&#8217;s RBT series. To provide a safe, high-performance solution for high-power testing, the latest RBT systems feature improved thermal management, redundant microcontrollers to ensure failsafe testing, and built-in UPS to ensure a proper shutdown sequence in case of input power failure. These features for battery pack testing are in addition to the safety features that are standard to Arbin battery test equipment.<\/p>\n<h2>\n\t\tAuxilaries and Optional Accessories Available to Enhance Testing\n\t<\/h2>\n\t<h3>CANBus<\/h3>\n<p><img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/06\/CAN-500x375.jpg\" alt=\"\" width=\"500\" height=\"375\" \/><\/p>\n<p>Arbin offers <strong>CANBus interface(s)\u00a0<\/strong>to allow real-time external control of the Arbin tester using CAN protocol. This feature allows for battery module\/pack communication with a BMS (battery management system) or for cell testing where the client needs external control via CAN.<\/p>\n\t<h3>MTCI<\/h3>\n<p><img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/images\/AUX-CAN-BUS_1CH_MTCI_1CH_RA_001C-500x199.png\" alt=\"CANBus MTCI Module\" width=\"500\" height=\"199\" \/><\/p>\n<p>The <strong>Temperature Chamber Interface (MTCI)<\/strong> allows the Arbin system to communicate with an approved third-party temperature\/environment chamber. Arbin&#8217;s software can turn the chamber on\/off and adjust the temperature during the test.<\/p>\n\t<h3>Control Power Supply<\/h3>\n<p><img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2022\/09\/testing-pouch-cells-with-a-cycler-and-battery-rack-from-arbin-500x404.jpeg\" alt=\"\" width=\"309\" height=\"250\" \/><\/p>\n<p>The Control Power Supply (<strong>CPS<\/strong>) provides multiple inputs that allow the Arbin test station to fully integrate with the facility, and allows the system to receive signals, display status with a safety tower light, and can be remotely shut down by the user.<\/p>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-0\" data-index=\"0\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-0\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\tDigital or Analog I\/O\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-1\" data-index=\"1\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-1\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\tTemperature Control\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-2\" data-index=\"2\" aria-selected=\"true\" aria-controls=\"fl-tabs--panel-2\" aria-expanded=\"true\" role=\"tab\" tabindex=\"0\">\t\t\t\tTemperature Measurement\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-3\" data-index=\"3\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-3\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\tAuxiliary Voltage Measurement\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-4\" data-index=\"4\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-4\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\tCANBus\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-tabs--label-5\" data-index=\"5\" aria-selected=\"false\" aria-controls=\"fl-tabs--panel-5\" aria-expanded=\"false\" role=\"tab\" tabindex=\"0\">\t\t\t\tUPS\t\t\t\t<\/a>\n\t\t\t\t\t\tDigital or Analog I\/O\n\t\t\t\t\t\t\t\t\t\t\t<strong>Digital Input\/Output (I\/O)<\/strong> channels allow the Arbin system to send and receive a digital relay (high\/low, on\/off) signal it interface with external hardware.\u00a0 They function independently so the user may flexibly assign them in any configuration with the main charge\/discharge test channels.<br \/>\nDigital I\/O are commonly used to interact with client facility hardware or external hardware used with flow battery applications.\n<strong>Analog Input\/Output (I\/O)<\/strong> channels allow the Arbin system to send and receive a (-10)-10V voltage signal or to interface with external hardware.\u00a0 They function independently so the user may flexibly assign them in any configuration with the main charge\/discharge test channels.<br \/>\nAnalog I\/O are commonly used to interact with client facility hardware or external hardware used with flow battery applications.\n\t\t\t\t\t\tTemperature Control\n\t\t\t\t\t\t\t\t\t\t\tArbin <strong>MZTC Multi-Chamber<\/strong> allows researchers to isolate individual or pairs of cells in their own fully independent min temperature chamber.<br \/>\n&#8211; Temperature range is [Ambient-10] to 60 degC.<br \/>\n&#8211; Interface trays are available for all cell types.<br \/>\n&#8211; Optionally add temperature sensors to mount on each cell.\n<p>Arbin&#8217;s <strong>3rd party chamber Interface module<\/strong> allows the Arbin tester to set the chamber temperature and record chamber reading automatically during the test and synchronize all data.\u00a0 This is compatible with many chamber brands, but please consult your Arbin sales engineer for details.<\/p>\n\t\t\t\t\t\tTemperature Measurement\n\t\t\t\t\t\t\t\t\t\t\tArbin offers <strong>thermocouple<\/strong> and <strong>thermistor<\/strong> sensor types to measure and record temperature during testing.\u00a0 They function independently so the user may flexibly assign them in any configuration with the main charge\/discharge test channels.\u00a0 All data is automatically synchronized with the cell charge\/discharge test data.\u00a0 Available sensor types include:<br \/>\n&#8211; K-Type Thermocouples<br \/>\n&#8211; T-Type Thermocouples<br \/>\n&#8211; PT100 Thermistor (NOTE: <em>PT100 thermistor inputs are compatible with Arbin MZTC Multi-Chamber<\/em>.)<br \/>\n&#8211; 10kOhm Thermistor\n\t\t\t\t\t\tAuxiliary Voltage Measurement\n\t\t\t\t\t\t\t\t\t\t\t<p><strong>Auxiliary Voltage inputs (auxV) <\/strong>may be added to any Arbin system to measure the voltage of additional reference electrodes in a multi-electrode cell or experiment.\u00a0 Any number of auxV inputs can be added to the Arbin system.\u00a0 They function independently so the user may flexibly assign them in any configuration with the main charge\/discharge test channels.\u00a0 All data is synchronized with main Arbin test data.<\/p>\n\t\t\t\t\t\tCANBus\n\t\t\t\t\t\t\t\t\t\t\t<p>Arbin offers <strong>CANBus interface(s)\u00a0<\/strong>to allow real-time external control of the Arbin tester using CAN protocol.\u00a0 This option is typically applied for battery modules and packs to communicate with a BMS (battery management system), but can also be utilized for cell testing is the client needs external control via CAN.<\/p>\n<p>NOTE: Additional methods of external control are available through Arbin&#8217;s optional TCP\/IP interface (Arbin &#8220;CTI&#8221;).<\/p>\n\t\t\t\t\t\tUPS\n\t\t\t\t\t\t\t\t\t\t\t<p>Arbin offers an optional <strong>UPS<\/strong> (uninterruptable power supply) that is intended to provide power for the PC used with the Arbin battery test equipment.\u00a0 This allows the PC and Arbin software to continue running during a brief power outage and tests can automatically resume when power is restored.\u00a0 Relatively longer power outages will safely shut down the PC.\u00a0 Tests can always be resumed manually after any stoppage.<\/p>\n<h2>\n\t\tContact Us Today for a Quote\n\t<\/h2>\n\t<p>Complete our contact form to request a quote or learn how battery test equipment from Arbin Instruments can meet your testing requirements.<\/p>\n\t\t\t<a href=\"https:\/\/arbin.com\/request-a-quote\/\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t\t\t\tRequest a quote\n\t\t\t\t\t<\/a>\n\n","protected":false},"excerpt":{"rendered":"<p>Regenerative Battery Test Series RBT Product Range Channel Voltage 60 &#8211; 1,500V Channel Current 50 &#8211; 1,000A Regenerative Efficiency\u00a0 &gt;90% Arbin&#8217;s Regenerative Battery Testing (RBT) series is specifically designed for testing high-power battery packs. Engineered with electric vehicles, military technology, and stationary grid storage in mind, these pack testing systems can simulate complex, real-world applications [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1910,"parent":6360,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"RBT Series | Arbin Instruments","_seopress_titles_desc":"RBT Series - Arbin Instruments","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":"","inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1633","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/pages\/1633","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/comments?post=1633"}],"version-history":[{"count":0,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/pages\/1633\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/pages\/6360"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/media\/1910"}],"wp:attachment":[{"href":"https:\/\/www.arbin.com\/ko\/wp-json\/wp\/v2\/media?parent=1633"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}