{"id":25736,"date":"2025-01-04T01:26:11","date_gmt":"2025-01-04T07:26:11","guid":{"rendered":"https:\/\/arbin.com\/?page_id=25736"},"modified":"2025-05-25T15:30:12","modified_gmt":"2025-05-25T20:30:12","slug":"mits-8-software","status":"publish","type":"page","link":"https:\/\/www.arbin.com\/de\/mits-8-software.html","title":{"rendered":"MITS 8 Software"},"content":{"rendered":"<h1>MITS 8 Software<br \/>L\u00f6sung Highlight<\/h1><p>MITS Pro is Arbin&#8217;s comprehensive battery testing software for all applications from the lab to the production floor. Developed by Arbin&#8217;s software engineers, it provides intuitive, complete control over testing systems to generate, analyze, and manage the data you need. Cycle cells, perform dynamic real-world simulations, and perform electrochemical experiments within the same user interface.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/ARBIN-Mits-8-Software.png\" alt=\"ARBIN Mits 8 Software\" itemprop=\"image\" title=\"ARBIN Mits 8 Software\" onerror=\"this.style.display='none'\"  \/>\n<h2>\n\t\tSoftware Highlights\n\t<\/h2>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/bb-plugin\/cache\/ARBIN-Software-Highlights-i1-square-86fba54707824e5a05bdb1c7acfe4c00-.png\" alt=\"ARBIN Software Highlights i1\" itemprop=\"image\" title=\"ARBIN Software Highlights i1\" onerror=\"this.style.display='none'\"  \/>\n\t\t<p>Logical, menu-driven programming for control types, termination conditions, and data logging conditions.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/bb-plugin\/cache\/ARBIN-Software-Highlights-i2-square-e80b4661a6f0e1b8bf9d12261ae157b3-.png\" alt=\"ARBIN Software Highlights i2\" itemprop=\"image\" title=\"ARBIN Software Highlights i2\" onerror=\"this.style.display='none'\"  \/>\n\t\t<p>Simulate a test directly from a text file of time-vs-current or time-vs-power data such as a drive profile (DST, FUDS, HPPC, etc.)<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/bb-plugin\/cache\/ARBIN-Software-Highlights-i3-square-5dc66608ad9fea2b1df43a5f662a6342-.png\" alt=\"ARBIN Software Highlights i3\" itemprop=\"image\" title=\"ARBIN Software Highlights i3\" onerror=\"this.style.display='none'\"  \/>\n\t\t<p>Control or monitor 3rd party hardware such as temperature chambers, or flow battery hardware such as pumps, flow meters, heaters, valves, etc.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/bb-plugin\/cache\/ARBIN-Software-Highlights-i4-square-a8aa6227a5eda5f2a8f081a4b6b05f09-.png\" alt=\"ARBIN Software Highlights i4\" itemprop=\"image\" title=\"ARBIN Software Highlights i4\" onerror=\"this.style.display='none'\"  \/>\n\t\t<p>Communicate with an internal battery management system (BMS) via CAN bus or SM bus protocol.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/bb-plugin\/cache\/ARBIN-Software-Highlights-i5-square-8944be2a668b7f079a718426575a3433-.png\" alt=\"ARBIN Software Highlights i5\" itemprop=\"image\" title=\"ARBIN Software Highlights i5\" onerror=\"this.style.display='none'\"  \/>\n\t\t<p>Parallel any number of channels to allow increased current handling, while automatically compiling data.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/bb-plugin\/cache\/ARBIN-Software-Highlights-i6-square-3aac0efb890d8e0b21ff9065a4b3f621-.png\" alt=\"ARBIN Software Highlights i6\" itemprop=\"image\" title=\"ARBIN Software Highlights i6\" onerror=\"this.style.display='none'\"  \/>\n\t\t<p>Many optional measurement inputs are available, such as additional reference electrodes, temperature measurements, and more.<\/p>\n<h2>\n\t\tPowerful Test Control\n\t<\/h2>\n\t<p>Arbin&#8217;s MITS Pro software suite provides the tools you need to effectively and efficiently control and monitor your testing operations.<\/p>\n<p>With its powerful test control, you can create a &#8220;test object&#8221; battery profile with pre-populated safety limits or create and fully customize testing profiles for your specific application.<\/p>\n<p>MITS Pro offers a convenient interface to add test steps, set the control type and value, set your termination conditions, and customize data logging intervals.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-PowerfullTC-1.png\" alt=\"Arbin-MITS8-PowerfullTC\" itemprop=\"image\" title=\"Arbin-MITS8-PowerfullTC\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-Data-Analyz-1.png\" alt=\"Arbin-MITS8-Data-Analyz\" itemprop=\"image\" title=\"Arbin-MITS8-Data-Analyz\" onerror=\"this.style.display='none'\"  \/>\n<h2>\n\t\tComplete Data Analysis\n\t<\/h2>\n\t<p>MITS Pro also offers the ability to view, plot, and analyze your battery test data in real-time, providing immediate information and insights.<\/p>\n<p>Chart templates and viewing options let you customize your real-time view while tests are running.<\/p>\n<p>To review test data later on, you can search your results by battery, operator, test profile, date, or other factors. You can also export your data into CSV or Excel format through the MITS Pro interface.<\/p>\n\t<p>Inhalts\u00fcbersicht<\/p>\n<h2>\n\t\tCreate and Manage Test Profiles\n\t<\/h2>\n\t\t<h3>01 MITS Pro<\/h3>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-TestProfile-img1.png\" alt=\"Arbin-MITS8-TestProfile-img1\" itemprop=\"image\" title=\"Arbin-MITS8-TestProfile-img1\" onerror=\"this.style.display='none'\"  \/>\n<p>MITS Pro allows fully customizable test profiles known as test &#8220;schedules&#8221; using logic-based parameters and dropdown menus.<\/p>\n\t\t<h3>02 MITS Pro: Add Steps<\/h3><p>Create a test &#8220;step&#8221; and select a control type from the dropdown list:<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-TestProfile-img2.png\" alt=\"Arbin-MITS8-TestProfile-img2\" itemprop=\"image\" title=\"Arbin-MITS8-TestProfile-img2\" onerror=\"this.style.display='none'\"  \/>\n\t<ul>\n<li>Current Voltage<\/li>\n<li>Power<\/li>\n<li>Load<\/li>\n<li>Rest (OCV)<\/li>\n<li>C-Rate<\/li>\n<li>CC-CV<\/li>\n<li>Voltage\/Current Ramp<\/li>\n<li>Voltage\/Current Staircase<\/li>\n<li>DC Internal Resistance<\/li>\n<li>Current\/Power Simulation<\/li>\n<li>Mathematical Formula<\/li>\n<li>Custom Current Pulse<\/li>\n<li>Set Variables (loops)<\/li>\n<li>And More<\/li>\n<\/ul>\n\t\t<h3>03 MITS Pro: Enter Control Value<\/h3><p>Create a test &#8220;step&#8221; and select a control type from the dropdown list:<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-TestProfile-img3.png\" alt=\"Arbin-MITS8-TestProfile-img3\" itemprop=\"image\" title=\"Arbin-MITS8-TestProfile-img3\" onerror=\"this.style.display='none'\"  \/>\n\t<p>Set a numeric control value or select one of over 90+ pre-defined meta variables, 16 user-defined meta variables, or mathematical formula for ultimate control of the test.<\/p>\n\t\t<h3>04 MITS Pro: Set Termination Condition(s)<\/h3><p>Create a test &#8220;step&#8221; and select a control type from the dropdown list:<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-TestProfile-img4.png\" alt=\"Arbin-MITS8-TestProfile-img4\" itemprop=\"image\" title=\"Arbin-MITS8-TestProfile-img4\" onerror=\"this.style.display='none'\"  \/>\n\t<p>Add one or more\u00a0termination conditions\u00a0from a drop-down list with the option to use logical AND &amp; OR functions. Create loops, nested loops, conditional branches and more.<\/p>\n\t\t<h3>05MITS Pro: Set Data Logging Criteria<\/h3>\t\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-TestProfile-img5.png\" alt=\"Arbin-MITS8-TestProfile-img5\" itemprop=\"image\" title=\"Arbin-MITS8-TestProfile-img5\" onerror=\"this.style.display='none'\"  \/>\n\t<p>Add and Customize one or more\u00a0data logging intervals\u00a0to automatically capture extra data during important events. Log based on change in Time, Voltage, or Current.<\/p>\n\t\t<h3>06&nbsp;MITS Pro: User Defined Meta Variable<\/h3>\t\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-TestProfile-img4.png\" alt=\"Arbin-MITS8-TestProfile-img4\" itemprop=\"image\" title=\"Arbin-MITS8-TestProfile-img4\" onerror=\"this.style.display='none'\"  \/>\n\t<p>Add one or more\u00a0&#8220;Set Value(s)&#8221;\u00a0to automatically:<\/p>\n<ol>\n<li>Save specific cycle capacity to MV_Udx and use it as a new C-Rate value in other cycles (example shown in step 3).<\/li>\n<li>Save Internal Resistance value to MV_Udx and use it anywhere in the schedule for calculation (example shown in step 6).<\/li>\n<li>Exit based on a specific capacity value (example shown in step 7).<\/li>\n<\/ol>\n<h2>\n\t\tData Analysis\/Real-Time Plotting\n\t<\/h2>\n<h2>\n\t\tData Management\n\t<\/h2>\n\t\t<h3>Secure Data Management<\/h3><p>MITS Pro provides multiple user accounts and permissions levels for lab management. All data save in the robust SQL database format. Store data locally centralized on a network server,\u00a0or in the cloud such as AWS.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-TestProfile-img9.png\" alt=\"Arbin-MITS8-TestProfile-img9\" itemprop=\"image\" title=\"Arbin-MITS8-TestProfile-img9\" onerror=\"this.style.display='none'\"  \/>\n\t\t<p>Centralized Networking<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-TestProfile-img10.png\" alt=\"Arbin-MITS8-TestProfile-img10\" itemprop=\"image\" title=\"Arbin-MITS8-TestProfile-img10\" onerror=\"this.style.display='none'\"  \/>\n\t\t<h3>Arbin Viewer<\/h3>\t\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-TestProfile-img11.png\" alt=\"Arbin-MITS8-TestProfile-img11\" itemprop=\"image\" title=\"Arbin-MITS8-TestProfile-img11\" onerror=\"this.style.display='none'\"  \/>\n\t\t<p>The Arbin Data Viewer program allows remote access to the Arbin testers. Users can search Arbin systems on their network and view their status. Additionally, authorized users can see the detailed status of each channel to review, assign, start, and stop tests remotely.<\/p>\n\t\t<p>A Console TCP Interface (CTI) is available to enterprise clients who wish to control the Arbin hardware directly using their own TCP\/IP commands or DLL interface.<\/p>\n<h2>\n\t\tSicherheit\n\t<\/h2>\n\t\t<h3>01Safety: Object File<\/h3><p>Data Watcher allows data to be viewed graphically in real time while tests are running.<\/p>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-Safety-img1.png\" alt=\"Arbin-MITS8-Safety-img1\" itemprop=\"image\" title=\"Arbin-MITS8-Safety-img1\" onerror=\"this.style.display='none'\"  \/>\n\t<p>Create DUT Object file.<\/p>\n\t\t<h3>02Safety: Global<\/h3>\t\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-Safety-img2.png\" alt=\"Arbin-MITS8-Safety-img2\" itemprop=\"image\" title=\"Arbin-MITS8-Safety-img2\" onerror=\"this.style.display='none'\"  \/>\n\t<p>Once the Object file is assigned to the test, global safety parameters are automatically populated based on the values in the Object file. Safety settings can be further tailored at the Step level when tighter control is needed. Arbin&#8217;s MITS Pro also uses intelligent battery behavior checks during testing to help prevent accidents.<\/p>\n\t\t<h3>03Safety: Global + Object<\/h3>\t\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-Safety-img3.png\" alt=\"Arbin-MITS8-Safety-img3\" itemprop=\"image\" title=\"Arbin-MITS8-Safety-img3\" onerror=\"this.style.display='none'\"  \/>\n\t<p>Once the Object file is assigned to the test, global safety parameters are automatically populated based on the values in the Object file. Safety settings can be further tailored at the Step level when tighter control is needed. Arbin&#8217;s MITS Pro also uses intelligent battery behavior checks during testing to help prevent accidents.<\/p>\n\t\t<h3>04Safety: Clamp Protections<\/h3>\t\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-Safety-img4.png\" alt=\"Arbin-MITS8-Safety-img4\" itemprop=\"image\" title=\"Arbin-MITS8-Safety-img4\" onerror=\"this.style.display='none'\"  \/>\n\t<p>Since Arbin testing systems have a redundant microcontroller for each module dedicated to monitoring safety limits, a secondary set of voltage limits may be set for each channel. This functions as a failsafe.<\/p>\n\t\t<h3>05Safety: Test Schedule<\/h3>\t\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-Safety-img5.png\" alt=\"Arbin-MITS8-Safety-img5\" itemprop=\"image\" title=\"Arbin-MITS8-Safety-img5\" onerror=\"this.style.display='none'\"  \/>\n\t<p>Create safety limits that immediately stop the test or create safety limits that will trigger periods of rest or cool down before continuing<\/p>\n<h2>\n\t\tLearn More About Arbin&#8217;s Complete Testing Solutions\n\t<\/h2>\n\t<p>Complete our contact form to request a quote or learn how battery test equipment and software from Arbin Instruments can meet your testing requirements.<\/p>\n\t\t\t<a href=\"\/de\/anfrage-angebot-html\/\" target=\"_blank\" rel=\"noopener\">\n\t\t\t\t\t\t\tAngebot anfordern\n\t\t\t\t\t<\/a>\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS8-Learnmore.png\" alt=\"Arbin-MITS8-Learnmore\" itemprop=\"image\" title=\"Arbin-MITS8-Learnmore\" onerror=\"this.style.display='none'\"  \/>","protected":false},"excerpt":{"rendered":"<p>MITS 8 SoftwareSolution Highlight MITS Pro is Arbin&#8217;s comprehensive battery testing software for all applications from the lab to the production floor. Developed by Arbin&#8217;s software engineers, it provides intuitive, complete control over testing systems to generate, analyze, and manage the data you need. Cycle cells, perform dynamic real-world simulations, and perform electrochemical experiments within [&hellip;]<\/p>","protected":false},"author":33,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"","_seopress_titles_title":"MITS 8 Software | Arbin Instruments","_seopress_titles_desc":"MITS Pro is Arbin\u2019s comprehensive battery testing software for all applications from the lab to the production floor. Developed by Arbin\u2019s software engineers, it provides intuitive, complete control over testing systems to generate, analyze, and manage the data you need. Cycle cells, perform dynamic real-world simulations, and perform electrochemical experiments within the same user interface.","_seopress_robots_index":"","inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-25736","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/pages\/25736","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/users\/33"}],"replies":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/comments?post=25736"}],"version-history":[{"count":1,"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/pages\/25736\/revisions"}],"predecessor-version":[{"id":26925,"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/pages\/25736\/revisions\/26925"}],"wp:attachment":[{"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/media?parent=25736"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}