{"id":161630,"date":"2026-08-28T04:29:53","date_gmt":"2026-08-28T09:29:53","guid":{"rendered":"https:\/\/www.arbin.com\/?page_id=161630"},"modified":"2026-08-28T05:25:24","modified_gmt":"2026-08-28T10:25:24","slug":"rbt-cell","status":"publish","type":"page","link":"https:\/\/www.arbin.com\/de\/battery-testing\/rbt-cell.html","title":{"rendered":"RBT-Zelle"},"content":{"rendered":"\n\n<a href=\"\/\">Home<\/a> > \n<a href=\"\/battery-testing.html\"> Battery Testing<\/a> > \nRBT-Cell Series\n\n\t<p>Regenerative Battery Testing System<\/p>\n<h1>\n\t\t\tRBT-Cell Series\t<\/h1>\n\t<p>High-current regenerative cycling and characterization for cell R&amp;D and quality control &#8211; <strong>up to 400 A per channel and 1,600 A in parallel<\/strong> &#8211; with <strong>100 ppm current measurement precision, true bipolar circuitry, and up to 83% regenerative efficiency<\/strong>.<\/p>\n\t\t\t<a href=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/arbin-brochure_rbt-cell.pdf\"  target=\"_blank\" rel=\"noopener\"    rel=\"noopener\">\n\t\t\t\t\t\t\tDownload the Brochure\n\t\t\t\t\t<\/a>\n\t\t\t<a href=\"https:\/\/www.arbin.com\/request-a-quote.html\"  target=\"_self\">\n\t\t\t\t\t\t\tGet Quote\n\t\t\t\t\t<\/a>\n<h2>\n\t\t\t4 &#8211; 64\t<\/h2>\n\t<p>Channels per chassis<\/p>\n<h2>\n\t\t\t\u00b10.015% \/ \u00b10.01%\t<\/h2>\n\t<p>FSR accuracy \/ precision<\/p>\n<h2>\n\t\t\t100 A &#8211; 400 A\t<\/h2>\n\t<p>Per channel, up to 1,600A in parallel<\/p>\n<h2>\n\t\t\t24-bit\t<\/h2>\n\t<p>1 part in 16,777,216<\/p>\n<h6>\n\t\t\tAccuracy you can audit\t<\/h6>\n\t<p>Accuracy and precision are published as two separate numbers, never blended into one, so you can verify the spec yourself instead of taking a vendor&#8217;s word for it.<\/p>\n<h6>\n\t\t\tIndependently verified\t<\/h6>\n\t<p>Designed and manufactured under an ISO 9001:2015-certified quality system, supported by an ISO\/IEC 17025-accredited testing and calibration laboratory.<\/p>\n<h6>\n\t\t\t35 years of instrumentation\t<\/h6>\n\t<p>Founded 1991. Arbin reinvests 30% of profits into R&amp;D, funding the precision architecture provided with every Arbin test station.<\/p>\n<h6>\n\t\t\tBuilt for any lab\t<\/h6>\n\t<p>Scalable channel density in a compact, air-cooled footprint, with open Python and C# API for the automation you already run.<\/p>\n<h2>\n\t\t\tHighlights of the RBT-Cell Series\t<\/h2>\n\t<p>Four hardware decisions that separate the RBT-Cell from a conventional high-current cycler.<\/p>\n<h2>\n\t\t\tRegenerative Energy Recovery\t<\/h2>\n\t<p>up to 83% returned to the grid<\/p>\n<h2>\n\t\t\tCut the energy cost of every cycle\t<\/h2>\n\t<p>SiC power stages return up to 83% of discharge energy to the facility grid. Channels share a common DC link within each module, so energy leaving a discharging channel is reused directly by a charging channel before anything is drawn from the mains, cutting the energy cost, and the HVAC load, of every cycle.<\/p>\n<h2>\n\t\t\tMarket Leading Specifications\t<\/h2>\n\t<p>100 ppm precision, 24-bit resolution<\/p>\n<h2>\n\t\t\tSee cell behavior &#8211; not tester uncertainty\t<\/h2>\n\t<p>Voltage and current measurement precision reaches <strong>100 ppm (\u00b10.01% FSR)<\/strong>, with \u00b10.01% FSR current accuracy and \u00b10.015% FSR voltage accuracy. 24-bit resolution provides fine control and measurement granularity across each current range, taken through 4-wire Kelvin connections.<\/p>\n<p>Subtle shifts in resistance, voltage response, and coulombic efficiency stay visible and repeatable even at full current.<\/p>\n<h2>\n\t\t\tFlexible Channel Paralleling\t<\/h2>\n\t<p>any number of channels<\/p>\n<h2>\n\t\t\tGroup channels for more current\t<\/h2>\n\t<p>Any combination of channels on a module can be connected in parallel to raise the current ceiling for a single test article, rather than choosing from a fixed set of pre-wired banks. Paralleled operation reaches up to <strong>1,600 A<\/strong> per module.<\/p>\n<p>Test a higher-current cell with the channels you already have, without a second system.<\/p>\n<h2>\n\t\t\tBuilt-In Safety Features\t<\/h2>\n\t<p>safety monitoring for every channel<\/p>\n<h2>\n\t\t\tIndependent monitoring, separate from control\t<\/h2>\n\t<p>Each channel module runs a dedicated microcontroller for precise control plus a second, redundant microcontroller that watches voltage safety limits on its own. Protective fuses sit on the IV channel boards, and thermoswitches with variable-speed fans hold the cabinet inside thermal limits.<\/p>\n<p>Device profiles set safety thresholds automatically and block a test from starting if reverse polarity is detected.<\/p>\n<h1>\n\t\t\tApplications and Test Methods\t<\/h1>\n\t<p>Up to 400 A per channel and 1,600 A paralleled, with regenerative circuitry that returns discharge energy to the grid across long high-current programs.<\/p>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/app-card-fast-charge-1.png\" alt=\"app card fast charge 1\" height=\"952\" width=\"1269\" title=\"app card fast charge 1\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<h5>\n\t\t\tHigh-current life cycle testing\t<\/h5>\n\t<p>Cycle large-format cells at up to 400 A per channel for months at a time. Regenerative circuitry returns up to 83% of discharge energy back to the system and the grid.<\/p>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/02-incoming-qc-cell-grading.jpg\" alt=\"02 incoming qc cell grading\" height=\"1200\" width=\"1600\" title=\"02 incoming qc cell grading\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<h5>\n\t\t\tIncoming QC and cell grading\t<\/h5>\n\t<p>Grade and sort incoming cells against your own pass criteria at production current. Up to 64 channels per chassis, each running its own schedule and safety limits.<\/p>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/rbt-pack-card3-drivecycle-bms-2-1.png\" alt=\"rbt pack card3 drivecycle bms (2) (1)\" height=\"1200\" width=\"1600\" title=\"rbt pack card3 drivecycle bms (2) (1)\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<h5>\n\t\t\tFast-charge and drive-cycle simulation\t<\/h5>\n\t<p>Upload drive cycles and duty profiles as time vs. current, power, or load with set points down to 10 ms. Lookup tables adjust the output against measured voltage, temperature, and state of charge.<\/p>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/04-automated-adaptive-testing.jpg\" alt=\"04 automated adaptive testing\" height=\"1200\" width=\"1600\" title=\"04 automated adaptive testing\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<h5>\n\t\t\tAutomated and adaptive testing\t<\/h5>\n\t<p>Drive the tester from your own software. ArbinCTI over TCP\/IP plus Lua scripting support BMS emulation, digital twins, and adaptive fast-charge strategies.<\/p>\n<p>&nbsp;<\/p>\n<h3>\n\t\t\tSupported Test Methods\t<\/h3>\n<h5>\n\t\t\tElectrochemical\t<\/h5>\n\t<ul>\n<li>GITT &#8211; galvanostatic intermittent titration<\/li>\n<li>PITT &#8211; potentiostatic intermittent titration<\/li>\n<li>Cyclic and linear sweep voltammetry<\/li>\n<li>Chrono-amperometry and potentiometry<\/li>\n<li>EIS to 100 kHz<\/li>\n<li>Symmetric-cell testing<\/li>\n<li>Multi-electrode and reference-electrode work<\/li>\n<\/ul>\n<h5>\n\t\t\tCycling and lifetime\t<\/h5>\n\t<ul>\n<li>Battery life cycle testing<\/li>\n<li>dQ\/dV analysis<\/li>\n<li>High-precision coulombic efficiency<\/li>\n<li>DCIR and pulse characterization<\/li>\n<li>Constant-power and constant-resistance cycling<\/li>\n<li>Real-world drive-cycle simulation<\/li>\n<li>Temperature-controlled cycling with chamber sync<\/li>\n<\/ul>\n<h5>\n\t\t\tProduction and QC\t<\/h5>\n\t<ul>\n<li>Incoming quality control<\/li>\n<li>Cell-level grading and sorting<\/li>\n<li>Formation and cell finishing<\/li>\n<li>End-of-line testing<\/li>\n<li>Fast-charge optimization<\/li>\n<\/ul>\n<h2>\n\t\t\tVoltage, Current, and Channel Ranges\t<\/h2>\n\t<p>One measurement specification, one software platform, across the full current span Arbin builds for cell testing &#8211; from 100 mA characterization work up to 1,600 A+ high-current cycling.<\/p>\n    <table>\n      <thead>\n        <tr>\n          <th>Voltage Range<\/th>\n          <th>Current Ranges per Channel<\/th>\n          <th>Channels per Chassis<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td rowspan=\"3\">0 to 6 V<\/td>\n          <td>100 A \/ 25 A<\/td>\n          <td>16, 32, 48<\/td>\n        <\/tr>\n        <tr>\n          <td>200 A \/ 50 A<\/td>\n          <td>8, 16, 24<\/td>\n        <\/tr>\n        <tr>\n          <td>400 A \/ 200 A \/ 50 A<\/td>\n          <td>4, 8, 12<\/td>\n        <\/tr>\n        <tr>\n          <td rowspan=\"3\">0 to 10 V<\/td>\n          <td>100 A \/ 25 A<\/td>\n          <td>16, 32<\/td>\n        <\/tr>\n        <tr>\n          <td>200 A \/ 50 A<\/td>\n          <td>8, 16<\/td>\n        <\/tr>\n        <tr>\n          <td>400 A \/ 200 A \/ 50 A<\/td>\n          <td>4, 8<\/td>\n        <\/tr>\n        <tr>\n          <td rowspan=\"3\">0 to 20 V<\/td>\n          <td>100 A \/ 25 A<\/td>\n          <td>16<\/td>\n        <\/tr>\n        <tr>\n          <td>200 A \/ 50 A<\/td>\n          <td>8<\/td>\n        <\/tr>\n        <tr>\n          <td>400 A \/ 200 A \/ 50 A<\/td>\n          <td>4<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  \n    Primary 0-to-X voltage ranges are listed above, and alternative voltage windows are also available:\n    \u22126 to +6 V and 2 to 6 V; \u221210 to +10 V and 2 to 10 V; and 2 to 20 V.\n    Available channel counts vary by voltage window.\n  \n<h2>\n\t\t\tComparing systems?\t<\/h2>\n\t<p>Four hardware parameters decide whether test data is suitable to draw a conclusion from. Here is where the RBT-Cell lands on each, and the question worth putting to every vendor on your shortlist.<\/p>\n\t<style>\n.lbts-ev-wrap{\n  overflow-x:auto;\n  -webkit-overflow-scrolling:touch;\n  border:1px solid #E3E6ED;\n  border-radius:4px;\n  background:#fff;\n}\n.lbts-ev{\n  width:100%;\n  min-width:840px;\n  border-collapse:collapse;\n  margin:0;\n  font-family:inherit;\n}\n.lbts-ev th{\n  background:#18214D;\n  color:#fff;\n  text-align:left;\n  padding:15px 20px;\n  font-weight:600;\n  font-size:14px;\n  letter-spacing:.02em;\n  line-height:1.4;\n}\n.lbts-ev th.lbts-ev-us{ background:#0052A0; }\n.lbts-ev td{\n  padding:20px;\n  border-bottom:1px solid #E3E6ED;\n  vertical-align:top;\n  font-size:15px;\n  line-height:1.55;\n  color:#4B4F58;\n}\n.lbts-ev tbody tr:last-child td{ border-bottom:none; }\n.lbts-ev .lbts-ev-param{\n  font-weight:600;\n  color:#18214D;\n  font-size:16.5px;\n  width:16%;\n}\n.lbts-ev .lbts-ev-why{ width:29%; }\n.lbts-ev .lbts-ev-ours{\n  width:27%;\n  background:#F4F8FC;\n}\n.lbts-ev .lbts-ev-ours strong{\n  display:block;\n  color:#18214D;\n  font-size:18px;\n  font-weight:600;\n  margin-bottom:5px;\n  font-variant-numeric:tabular-nums;\n}\n.lbts-ev .lbts-ev-ask{\n  width:28%;\n  color:#5C6577;\n  font-style:italic;\n}\n@media(max-width:700px){\n  .lbts-ev td{ padding:16px; font-size:14.5px; }\n  .lbts-ev th{ padding:13px 16px; }\n}\n<\/style>\n  <table>\n    <thead>\n      <tr>\n        <th scope=\"col\">Parameter<\/th>\n        <th scope=\"col\">Why it decides your data<\/th>\n        <th scope=\"col\">RBT-Cell<\/th>\n        <th scope=\"col\">Ask any vendor<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td>Resolution<\/td>\n        <td>The smallest change the circuitry can detect. Too coarse and a resistance spike near end of life, or a dip in coulombic efficiency, simply is not in your data.<\/td>\n        <td><strong>24-bit<\/strong>1 part in 16,777,216. Voltage and current alike.<\/td>\n        <td>How many bits? 16-bit is the common industry standard, and it is 256 times coarser.<\/td>\n      <\/tr>\n      <tr>\n        <td>Precision<\/td>\n        <td>The noise floor. Noise obscures exactly the features dQ\/dV and high-precision coulombic efficiency exist to reveal.<\/td>\n        <td><strong>&plusmn;0.01% FSR<\/strong>100 ppm, specified separately for voltage, current, and time.<\/td>\n        <td>Is precision a hardware specification, or derived from averaged calculations and slow logging that hide the noise?<\/td>\n      <\/tr>\n      <tr>\n        <td>Accuracy<\/td>\n        <td>Whether the number is right, not merely repeatable. A tester can be precisely wrong all day.<\/td>\n        <td><strong>&plusmn;0.015% FSR<\/strong>Published as its own figure, never merged with precision.<\/td>\n        <td>Can you give accuracy and precision as two separate numbers?<\/td>\n      <\/tr>\n      <!-- ============================================================\n           TEMPERATURE STABILITY ROW - NEEDS ENGINEERING SIGN-OFF.\n           The ~0.000185% \/ degC figure is from the \"How to Evaluate\n           Battery Test Equipment\" white paper, not the LBTS21\n           datasheet. Confirm it applies to LBTS, or delete this\n           entire <tr> block.\n      ============================================================ -->\n      <\/tr><tr>\n        <td>Temperature stability<\/td>\n        <td>Ambient drift skews a test that runs for months. Gradual change tilts the data; sudden change steps it.<\/td>\n        <td><strong>~0.000185% \/ &deg;C<\/strong>Patented shunt design, developed with Sandia&#8217;s metrology group.<\/td>\n        <td>What is the temperature coefficient of your accuracy specification?<\/td>\n      <\/tr>\n      <!-- ===================== end sign-off row ===================== -->\n    <\/tbody>\n  <\/table>\n<h2>\n\t\t\tSoftware and Safety\t<\/h2>\n\t<p>The two questions a lab asks after the specifications check out: can my team actually drive it, and what happens when a cell misbehaves.<\/p>\n<h2>\n\t\t\tMITS Software\t<\/h2>\n<p>MITS scales from basic charge-discharge cycling to complex protocols with nested conditions. Most tests can be built through the menu-driven interface, while Lua scripting and ArbinCTI are available for advanced automation and external control<\/p>\n<ul>\n<li>\u2713 30+ programmable control types, 90+ meta variables, and up to 9 nested loops<\/li>\n<li>\u2713Up to 127 reusable sub-schedules, so a validated procedure gets called rather than rebuilt<\/li>\n<li>\u2713Adaptive logging raises acquisition rate during transients and state transitions<\/li>\n<li>\u2713DataWatcher queries the SQL database directly &#8211; filter by channel, barcode, or cycle count, overlay up to 9 plots<\/li>\n<li>\u2713PostgreSQL, Microsoft SQL Server, and Apache Kafka streaming<\/li>\n<li>\u2713ArbinCTI TCP\/IP API plus Lua scripting for BMS emulation and adaptive control<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.arbin.com\/mits-10-software.html\">Explore MITS Software \u2192<\/a><\/p>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2025\/01\/Arbin-MITS10-Manage-Test-1-1024x519.png\" alt=\"Arbin-MITS10-Manage-Test-1\" height=\"519\" width=\"1024\" title=\"Arbin-MITS10-Manage-Test-1\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<h2>\n\t\t\tSafety Architecture\t<\/h2>\n<p>Protection is distributed across channel hardware, an independent controller, and step-level software limits. Critical safeguards remain active independently of the test sequence.<\/p>\n<ul>\n<li>\u2713Independent safety monitoring checks voltage, current, and temperature limits without relying on the test control loop<\/li>\n<li>\u2713Hardware E-Stop with all-pole disconnection, plus a dry-contact circuit for facility-wide remote trip<\/li>\n<li>\u2713Hardware voltage clamps on high-current modules; protective fuses in every I\/V channel board<\/li>\n<li>\u2713Test Object profiles auto-set thresholds from the cell spec and block a test on reverse polarity<\/li>\n<li>\u2713Behavioral checks flag abnormal rates, voltage excursions, and capacity anomalies<\/li>\n<li>\u2713Tri-color light tower, audible alarms, thermoswitches, variable-speed ventilation<\/li>\n\n<\/ul>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/mits10_safetywindow.png\" alt=\"mits10 safetywindow\" height=\"661\" width=\"1042\" title=\"mits10 safetywindow\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/plugins\/bb-plugin\/img\/pixel.png\" alt=\"\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<h2>\n\t\t\tAuxiliaries and Optional Accessories Available to Enhance Testing\t<\/h2>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/auxcard-productpage-thermalmztc-1.png\" alt=\"auxcard productpage thermalmztc 1\" height=\"760\" width=\"1200\" title=\"auxcard productpage thermalmztc 1\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<h2>\n\t\t\tThermal and Environmental\t<\/h2>\n\t<ul>\n<li>MZTC &#8211; 8 independently controlled mini-chambers, 10\u00b0C to 60\u00b0C at 20\u00b0C ambient<\/li>\n<li>Holders for coin, cylindrical, pouch, and custom cell formats; up to 8 cells per chamber<\/li>\n<li>Seamlessly communicate and control third-party temperature chambers in real-time<\/li>\n<li>Synchronized multi-channel test logic; temperature-driven step control and automated standby modes<\/li>\n<li>Chamber temperature and humidity logged alongside electrical measurements for complete test traceability<\/li>\n<\/ul>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/aux-cti-card.png\" alt=\"aux cti card\" height=\"760\" width=\"1200\" title=\"aux cti card\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<h2>\n\t\t\tCTI &#038; External Controls\t<\/h2>\n\t<ul>\n<li>Custom Test Instructions (CTI) &#8211; script test logic beyond standard commands, written in C#\/.NET<\/li>\n<li>Application Programming Interface (API) &#8211; connect MITS Pro to LIMS, MES, or in-house systems for automated data exchange<\/li>\n<li>External device control &#8211; drive third-party power supplies, DAQs, or lab instruments directly from the test schedule<\/li>\n<li>Custom hardware drivers &#8211; integrate vendor-specific communication protocols not natively supported out of the box<\/li>\n<\/ul>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/auxcard-productpage-aux-2.png\" alt=\"auxcard productpage aux 2\" height=\"760\" width=\"1200\" title=\"auxcard productpage aux 2\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<h2>\n\t\t\tAuxiliaries\t<\/h2>\n\t<ul>\n<li>Temperature sensing &#8211; real-time thermal monitoring for chambers and cell surfaces<\/li>\n<li>Auxiliary voltage inputs &#8211; monitor individual cell voltages or reference electrodes within packs<\/li>\n<li>Analog &amp; Digital I\/O &#8211; control external devices like pumps, fans, valves, and safety interlocks<\/li>\n<li>CAN Bus interface &#8211; direct communication with Battery Management Systems<\/li>\n<li>SMBus interface &#8211; read and write smart battery registers during testing<\/li>\n<li>Uninterruptible Power Supply (UPS) &#8211; detect power loss and safely pause or resume tests<\/li>\n<\/ul>\n<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/auxcard-productpage-holders-2.png\" alt=\"auxcard productpage holders 2\" height=\"760\" width=\"1200\" title=\"auxcard productpage holders 2\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t<\/figure>\n<h2>\n\t\t\tHolders &#038; Fixtures\t<\/h2>\n\t<ul>\n<li>Custom-engineered holders for coin, cylindrical, pouch, and application-specific cell formats<\/li>\n<li>Support high-current test configurations; flexible contact design accommodates diverse cell geometries<\/li>\n<li>Modular rack systems enable scalable test density and simplified reconfiguration across channels<\/li>\n<\/ul>\n\t<style>\n  .lbts-proof-quotes{display:grid;grid-template-columns:repeat(3,1fr);gap:22px;margin:0 0 24px;}\n  @media(max-width:800px){.lbts-proof-quotes{grid-template-columns:1fr;}}\n<\/style>\n<h2>Evaluated Side by Side Against Other Testers<\/h2>\n    <blockquote>&ldquo;We did side-by-side comparisons of Arbin and other tester technology. Armed with this data, we moved forward with confidence using Arbin for what is critical to our electrification future [EV].&rdquo;<\/blockquote>\n    &#8211; T. MillerFord Motor Company\n    <blockquote>&ldquo;With Arbin, you can see minute changes in the battery and this gives researchers better predictability of when the end of life will occur in a reduced amount of time.&rdquo;<\/blockquote>\n    &#8211; J. NovakSandia National Laboratories\n    <blockquote>&ldquo;High precision measurements are not the only answer to understanding battery life, but it is a key component. Sandia National Lab brings their expertise in metrology and precision measurements and has helped Arbin as they&rsquo;ve designed the new series of testers.&rdquo;<\/blockquote>\n    &#8211; S. FerreiraSandia National Laboratories\n  <img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2026\/08\/rd-100-award-seal-pic-copy.jpg\" alt=\"R&#038;D 100 Award badge\"\/>\n    <h4>R&amp;D 100 Award &mdash; high-precision tester development<\/h4>\n    <p>Through a three-year ARPA-E project funded by the U.S. Department of Energy, Arbin worked with Ford Motor Company, Sandia National Laboratories to develop high-precision battery testing at currents up to 200 A. The resulting architecture was subsequently extended across lower-current applications and now underpins the LBTS-Cell platform.<\/p>\n<h2>\n\t\t\tTell us what you&#8217;re testing\t<\/h2>\n\t<p>Share your cell format, voltage and current requirements, channel count, and test objectives. An Arbin sales engineer will recommend the appropriate system configuration and supporting options.<\/p>\n\t\t\t<a href=\"https:\/\/www.arbin.com\/request-a-quote.html\"  target=\"_self\">\n\t\t\t\t\t\t\tGet Quote for RBT-Cell\n\t\t\t\t\t<\/a>\n\t\t\t<a href=\"https:\/\/www.arbin.com\/contact-us.html\"  target=\"_self\">\n\t\t\t\t\t\t\tContact Us To Learn More\n\t\t\t\t\t<\/a>\n<h2>\n\t\t<a href=\"\/battery-testing\/\" title=\"Related Battery Testing Solutions\"  target=\"_self\">\n\t\t\tRelated Battery Testing Solutions\t\t<\/a>\n\t<\/h2>\n\t\t<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<a href=\"\/battery-testing\/lbts-mztc.html\"  target=\"_self\" itemprop=\"url\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.arbin.com\/wp-content\/uploads\/2024\/12\/LBTS21324-TC-Right-1920.png\" alt=\"LBTS21324-TC-Right-1920\" height=\"3300\" width=\"1920\" title=\"LBTS21324-TC-Right-1920\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t\t\t\t<\/a>\n\t<\/figure>\n<h3><a href=\"\/battery-testing\/lbts-mztc.html\" target=\"_self\">LBTS-MZTC<\/a><\/h3><p>Turn-key high-precision cell testing solution integrated with Arbin&#8217;s patented Cell-Isolating Thermal Chamber<\/p>\n\t\t<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<a href=\"\/battery-testing\/lbts-cell-high-volume.html\"  target=\"_self\" itemprop=\"url\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dev.arbin.com\/wp-content\/uploads\/2024\/09\/ARBIN-LBTS-Cell-High-Volume.png\" alt=\"\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t\t\t\t<\/a>\n\t<\/figure>\n<h3><a href=\"\/battery-testing\/lbts-cell-high-volume.html\" target=\"_self\">LBTS-Cell High Volume<\/a><\/h3><p>The perfect solution for high-volume testing.\u00a0Ideal for incoming quality control and large-scale testing.<\/p>\n\t\t<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<a href=\"\/battery-testing\/rbt-cell.html\"  target=\"_self\" itemprop=\"url\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dev.arbin.com\/wp-content\/uploads\/2024\/09\/ARBIN-RBT4-Cell.png\" alt=\"\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t\t\t\t<\/a>\n\t<\/figure>\n<h3><a href=\"\/battery-testing\/rbt-cell.html\" target=\"_self\">RBT-Cell<\/a><\/h3><p>Efficient regenerative battery cell testers <strong>from 100 A to 1,600 A, with 100ppm precision<\/strong>, built-in safety, and flexible channel paralleling.<\/p>\n\t\t<figure itemscope itemtype=\"https:\/\/schema.org\/ImageObject\">\n\t\t\t\t<a href=\"\/battery-testing\/rbt4-module.html\"  target=\"_self\" itemprop=\"url\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dev.arbin.com\/wp-content\/uploads\/2024\/09\/ARBIN-RBT4-ModulePack-Series.png\" alt=\"\" onerror=\"this.style.display='none'\" loading=\"lazy\" \/>\n\t\t\t\t<\/a>\n\t<\/figure>\n<h3><a href=\"\/battery-testing\/rbt4-module.html\" target=\"_self\">RBT-Module Series<\/a><\/h3><p>The RBT system ensures high power density and efficiency, while its regenerative circuitry returns power to the grid, making it economical for testing.<\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>Home > Battery Testing > RBT-Cell Series Regenerative Battery Testing System RBT-Cell Series High-current regenerative cycling and characterization for cell R&amp;D and quality control &#8211; up to 400 A per channel and 1,600 A in parallel &#8211; with 100 ppm current measurement precision, true bipolar circuitry, and up to 83% regenerative efficiency. Download the Brochure [&hellip;]<\/p>\n","protected":false},"author":21,"featured_media":0,"parent":22207,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"Regenerative Battery Cell Tester | RBT-Cell | Arbin","_seopress_titles_desc":"Efficient regenerative battery cell testers from 100 A to 1,600 A, with 100ppm precision, built-in safety, and flexible channel paralleling. See specs.","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":"","inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-161630","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/pages\/161630","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/users\/21"}],"replies":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/comments?post=161630"}],"version-history":[{"count":15,"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/pages\/161630\/revisions"}],"predecessor-version":[{"id":161938,"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/pages\/161630\/revisions\/161938"}],"up":[{"embeddable":true,"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/pages\/22207"}],"wp:attachment":[{"href":"https:\/\/www.arbin.com\/de\/wp-json\/wp\/v2\/media?parent=161630"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}